background image

12

Such items must be clearly identified as having been sterilized, 
both by a tag on the item itself and by a statement in the 
accompanying correspondence. Waring will not accept delivery 
of any return unless it is so identified.

Replacement parts for your out-of-warranty repairs are obtainable 
at the address below.

WARRANTY

LIMITED TWO YEAR MOTOR WARRANTY 
LIMITED ONE YEAR PARTS AND LABOR WARRANTY

 

(U.S. and Canada Only)

Waring warrants every new Waring

®

 Commercial Blender to be 

free from defects in material and workmanship for a period of 
one year from the date of purchase when used with foodstuffs, 
nonabrasive liquids (other than detergents) and nonabrasive 
semiliquids, providing it has not been subject to loads in excess 
of the indicated rating. In addition, the motor in this appliance has 
a full two year warranty.

Under this warranty, Waring will repair or replace any part that, 
upon our examination, is defective in materials or workmanship, 
provided the product is delivered prepaid to the Waring Service 

This warranty does not: a) apply to any product that has become 
worn, defective, damaged or broken due to misuse or due to 
repairs or servicing by other than the Waring Service Center or 
a Factory Approved Service Center, or due to abuse, misuse, 
overloading or tampering; or b) cover incidental or consequential 
damages of any kind.

The warranty is applicable only to appliances used in the United 
States or Canada; this supersedes all other express product 
warranty or warranty statements. For Waring products sold 
outside of the U.S. and Canada, the warranty is the responsibility 
of the local importer or distributor. This warranty may vary 
according to local regulations.

Warning: 

This warranty is void if appliance is used on Direct

Current (DC).

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for Torq 2.0 TBB Series

Page 1: ...ent of this product always read the instruction book carefully before using Para su seguridad y para disfrutar plenamente de este producto siempre lea las instrucciones cuidadosamente antes de usarlo Afin que votre appareil vous procure en toute sécurité beaucoup de satisfaction lire attentivement les directives avant de l utiliser TBB160 www calcert com sales calcert com 1 888 610 7664 0 5 10 15 ...

Page 2: ...unctions or is dropped or damaged in any manner Return appliance to the nearest authorized service facility for examination repair or electrical or mechanical adjustment 8 The use of attachments not recommended by the appliance manufacturer may cause hazards 9 Do not use outdoors 10 Do not let cord hang over edge of table or counter where it can inadvertently be pulled on or tripped over or touch ...

Page 3: ...OT blend oil or oil based products such as peanut butter for more than 5 minutes 26 Never remove blender jar from base unit until the blade and coupling have completely stopped 27 CAUTION In order to avoid a hazard due to inadvertent resetting of the thermal cutout this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly s...

Page 4: ...OTE Use of an adapter is not permitted in Canada BLENDER SPECIFICATIONS Capacity 48 oz Working Capacity Rating 220 240 Volts 60 Hz 13 0 Amps Base Material Polycarbonate Bearing High Precision Ball Bearing Cord 6 Foot Three Conductor Ground Cord with Strain Relief in Base Overall Height 17 Inches cULus NSF Listed Operating Cycle 1 min ON 3 min OFF Controls TBB145 TBB160 LO 20 500 HI 24 000 PULSE 24...

Page 5: ...ink during operation G Power Cord not shown Control Panel Variations TBB145 Toggle Switch Controls with HI LO OFF PULSE TBB160 Electronic Touchpad Controls with HI LO STOP PULSE 60 Second Timer LED with Up Down TBB175 Variable Speed Control Dial PULSE PULSE Button Feature PULSE overrides HI speed for a quick burst of power All parts that come in contact with food are BPA free A B C D E F F F TBB14...

Page 6: ...osition Always use HI or PULSE for crushing ice 5 When blending is complete set toggle switch to OFF position 6 This blender is equipped with a PULSE option Hold toggle switch in down position to engage PULSE function Unit will run on MAX speed until the toggle switch is released NOTE This blender utilizes a Slow Start feature When beginning HI or LO operation the unit will start in a lower speed ...

Page 7: ...ou set a time it will be kept and is repeatable until reset or unplugged NOTE If you want to increase or decrease the time while the timer is counting down press the up or down arrow symbols as needed Time will increase in 1 second intervals Pressing the PULSE or STOP button during timer mode will stop the motor regardless of how much time is left on the timer 6 For continuous operation press eith...

Page 8: ...g The LED will blink during blending When blending is complete press the START STOP button to stop blending You may wish to start at a low speed and increase to a higher setting 6 For momentary operation press the PULSE button motor will run on MAX speed until the button is released NOTE This blender utilizes a Slow Start feature When beginning HI or LO operation the unit will start in a lower spe...

Page 9: ...nue use and contact a certified Waring Customer Service Center CLEANING AND SANITIZING INSTRUCTIONS THE CONTAINER MUST BE CLEANED AND DRIED AFTER EACH USE OF THE BLENDER ACCORDING TO THE FOLLOWING INSTRUCTIONS FAILURE TO DO SO MAY ALLOW RESIDUE OF PROCESSED MATERIAL TO COLLECT ON THE INTERNAL SEALS OF THE BLADE ASSEMBLY RENDERING THEM INEFFECTIVE Wash rinse sanitize and dry container prior to init...

Page 10: ...washing solution Fill container one quarter full with fresh washing solution cover with lid only place on motor base and run on HI speed for two 2 minutes Empty container 3 Repeat step 2 using clean rinse water in place of washing solution IMPORTANT NOTE IN ORDER TO MINIMIZE POSSIBILITY OF SCALDING TEMPERATURE OF WASHING SOLUTION AND RINSE WATER SOLUTION PRODUCT DILUTION IN WATER TEMPERATURE Washi...

Page 11: ... parts to air dry TO CLEAN AND SANITIZE MOTOR BASE 1 UNPLUG POWER CORD Wipe down exterior surfaces of motor base with soft cloths or sponges dampened with washing solution rinse water and sanitizing solution Prevent liquid from running into motor base by wringing all excess moisture from cloths or sponges before using them DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION RINSE WATER OR SANITIZING SOL...

Page 12: ...ear warranty Under this warranty Waring will repair or replace any part that upon our examination is defective in materials or workmanship provided the product is delivered prepaid to the Waring Service This warranty does not a apply to any product that has become worn defective damaged or broken due to misuse or due to repairs or servicing by other than the Waring Service Center or a Factory Appr...

Reviews: