background image

Solid Kynar, Non-Metallic 

ANSI Centrifugal Pumps 

WANNER ENGINEERING, INC.

1204 Chestnut Avenue, Minneapolis, MN  55403 

TEL:  (612)  332-5681    FAX:  (612)  332-6937   

TOLL-FREE FAX [US only]: (800) 332-6812 

www.stancorpump.com 

 

email: [email protected]

W0439

Installation and 

Operation Manual

SCK-991-2400B

Summary of Contents for STAN-COR

Page 1: ...Pumps WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www stancorpump com email sales wannereng com W0439 Install...

Page 2: ...ynar 370 The physical properties of this material is more than adequate to withstand all loadings encountered through the rated pressure and temperature range for the pump Solid filled Kynar 370 resis...

Page 3: ...g base plates refer to the Hydraulic Institute Standards Coupling Alignment Good service life of the pump and driver depends upon good alignment through the flexible coupling If the electric motor was...

Page 4: ...connected to the branch of the tee to permit flushing of the pump before removing it from the line Piping Suction Properly selected and installed suction piping is extremely important to eliminate vi...

Page 5: ...ing the shaft coupling Incorrect pump rotation for even a short time will dislodge the impeller and damage the impeller or casing or both The pump shaft must turn clockwise when viewed from the motor...

Page 6: ...as seen from the impeller end of the pump 13 Using a firm grip spin the impeller to the left impacting the wrench on the work table After a few impacts the impeller should screw off easily 14 Remove t...

Page 7: ...onto the shaft until it seats against the shoulder Press only on the inner race 4 Lubricate the sealing element of the outboard oil seal 21 grease on outside of seal and inside of housing Press the oi...

Page 8: ...cover over the shaft Be sure that the sleeve drive pin 9 engages the notch in the sleeve I D Secure the adaptor to the frame with four bolts 39 and nuts 40 C 24 Check that the O ring 8 is installed in...

Page 9: ...Gauge sight oil Oiler assembly 24 Plug pipe 25 Breather 26 Deflector 27 Adaptor 28 Plate mounting 29 Stud mounting plate 30 Gland 31 Plats front 32 Support casing 33 Flange split 34 Flange split 35 Sc...

Page 10: ...uction line not immersed enough x x x Impeller damaged x x x Shaft packing or seal defective x x Impeller diameter too small x x Impeller diameter too large x x Excessive amount of air or gas in liqui...

Page 11: ...lush may be required when solids are excessive Stationary Seat Cracked or Chipped Check the stationary seat element for cracks or chips on the sealing surface which could cause excessive wear and leak...

Page 12: ...e manufacturers of these components 2 Normal wear and or damage caused by or related to abrasion corrosion abuse negligence accident faulty installation or tampering in a manner which impairs normal o...