Instruction Handbook KL
Chapter 9
BA KL V11 en
10/2014
page 9-22
9.7.5
Mechanical seal KL30
– KL100
Dismounting:
1.
Remove joint (
chapter 9.6) and pull off distance ring 1017.
2.
Remove distance ring. For mechanical seals independent of rotational direction: undo the
bolts on the lock ring.
3.
Withdraw the complete mechanical seal.
4.
Clean sealing seat by means of a standard solvent.
Mounting:
1.
Press stationary part complete with O-ring evenly into the seal plate 1029. The groove in the
sealing body must engage in dowel pin 1030. Insert mechanical seal housing 1028 with O-
Ring 1019 in bearing. Slide dynamic sealing element onto shaft. The wire lug on the spring
must engage in the groove of the sealing element. Slide on distance ring.
2.
Fit and secure snap ring 1017.
3.
Fit joint.
4.
Reassemble pump by following the instructions for disassembly in reverse order.
Possible damage
For mechanical seals independent of rotational direction: tighten the bolts on the lock ring
after the joint has been fitted.
Fig. 9-20
ATTENTION