74
W&T
IP-Watcher 2x2 Digital PoE
8.2 Factory defaults
Some situations require that the IP-Watcher be restored to its
factory default settings. There are two ways to do this:
.
Using Web-Based Management
.
Using the Reset jumpers
Restoring the factory default settings returns the unit to
1
its state as shipped from the factory. First write down all
the settings so that you can later restore the configuration as
needed.
8.2.1 Web-Based Management
To restore the factory default settings using Web-Based Ma-
nagement, log in to the configurationpages and navigate to
Config >> Session Control >> LogOut
On the page shown in the main window you can click on the
Restore Defaults
button to return the unit to its original
settings.
8.2.2 Reset jumpers
If you are unable to restore the factory default settings using
the Web interface, you can load the factory settings by jumpe-
ring the Rest jumper contacts.
For this you must open the device by pulling out the circuit
boards together with the front panel.
Always disconnect the device from power first before
1
opening it. Otherwise the IP-Watcher could be damaged.
You will see one open jumper contacts on the upper board.
Close this contact.
Apply power to the IP-Watcher for approx. 15s. The device is
now reset to its factory defaults. The LEDs on the front panel
will flicker irregularly during this procedure.