28
Technical details Economic
Technical details
Door
latch
Ba
I/II
Nominal
capacity*
7
kW
Diameter tube for combustion gases
150
mm
Maximum lumber supply in the stove
3
kg
Maximum brown coal supply
3
kg
Volume of the combustion chamber
0.08
m3
Surface bottom of combustion chamber
0.2
m2
* a nominal heat of 7 kW is obtained with a chimney draught of 0.12 mbar
Fuel
wood logs, 30 x 10 cm
brown coal
Maximum
supply
3
pieces
4
pieces
Primary
air
valve
max.
max.
Secondary
air
outlet
max.
max.
Fuel
burning
period
about 1
hour
about 1
hour
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When door is closed
logs
brown coal
Flue
gas
quantity
4,2
g/s
12,2
g/s
Flue
gas
temperature
330
˚C
298
°C
Pre-pressure
0.12
mbar
0,12
mbar
Yield
78.7
%
79,3
%
CO at 13% O2
0.06
%
0,09
%
Particulate
matter
--
mg/m3
--
mg/m3
Certificate Institute 1625. Test standard EN 13229. Test report no. RRF-400169
Summary of Contents for ECONOMIC 75
Page 13: ...13 NL ...
Page 16: ...16 User s Guide and Installation Manual Economic GB ...
Page 30: ...30 ...
Page 31: ...31 FR Mode d emploi et instructions d installation Economic FR ...
Page 46: ...46 Gebrauchsanweisung und Installationsvor schriften Economic DE ...
Page 60: ...60 Technische tekeningen Technical drawings Dessins techniques Technische Zeichnungen ...
Page 61: ...Technische tekeningen Technical drawings Dessins techniques Technische Zeichnungen 61 ...
Page 62: ...62 ...
Page 63: ......