background image

1

INSTALLATIE EN BEDIENINGSVOORSCHRIFTEN VOOR: 

 

INSTALLATION AND OPERATION INSTRUCTIONS FOR: 

 

BORDEAUX 

 

www.wanders.com

NL GB

Summary of Contents for BORDEAUX

Page 1: ...1 INSTALLATIE EN BEDIENINGSVOORSCHRIFTEN VOOR INSTALLATION AND OPERATION INSTRUCTIONS FOR BORDEAUX www wanders com NL GB...

Page 2: ...VAN DE GASLEIDING 2 5 ONDERHOUD 2 6 TTB 2 7 HOUTSET 2 8 AFSTANDSBEDIENING 2 9 GEBRUIKS AANWIJZING AFSTANDSBEDIENING 3 0 GEBRUIKERS HANDLEIDING 3 1 INGEBRUIK STELLEN VAN DE KACHEL 3 2 BUITEN WERKING ST...

Page 3: ...te worden De kachel dient geplaatst aangesloten en gecontroleerd te worden door een erkend gas technisch installateur Instelwaarden veranderen en overige aanpassingen mogen alleen gebeuren door een er...

Page 4: ...k 5 Plaats de kachel nu in de ombouw en schuif het schoorsteen aansluitstuk weer op zijn plaats 6 Maak nu de gasaansluiting volgens de voorschriften zie gasaansluiting 7 Controleer alle gasaansluiting...

Page 5: ...randings kamer Het keramisch glas kan gereinigd worden met een speciaal schoonmaakmiddel voor keramische kookplaten Indien een houtblok stuk is dient deze vervangen te worden Indien er sprake is van e...

Page 6: ...6 Fig 4a Fig 4b Fig 4c...

Page 7: ...links onderin het toestel voordat u de sierlijst plaatst fig 6 Schuif de kabel tussen de buitenmantel en de bodem plaat van de verbrandingskamer Fig 6 ONTVANGER LED KABEL Aansluiting motor STEKKERS V...

Page 8: ...komen De sensor in de afstands bediening meet de temperatuur in de ruimte deze wordt met de ingestelde temperatuur vergeleken de ontvanger krijgt een signaal en stelt de vlam hoogte in naar gelang de...

Page 9: ...het toestel automatisch op waakvlam gedraaid als er later weer een signaal komt wordt het toestel weer ingeschakeld Aanwijzingen Voordat men AUTO of TIMER inschakelt moet men met de toetsen en de ontv...

Page 10: ...eval dan dient U deze handelingen te herhalen Indien de waakvlam brand de ontstekingsknop nog 30 seconden ingedrukt houden En daarna loslaten de waakvlam moet nu blijven branden Dan de knop A nog verd...

Page 11: ...f als de deur open staat De kachel mag alleen gerepareerd worden met originele onderdelen geleverd door de fabrikant en reparaties mogen alleen uitgevoerd worden door een erkend installateur Aan de ho...

Page 12: ...ventileert 3 7 Onderhoud Om de veiligheid en de goede werking van de kachel te kunnen garanderen dient de kachel jaarlijks door een erkend vakman gecontroleerd en gereinigd te worden Het brandergedee...

Page 13: ...3 16 320 1 4 0 445 6 AT G20 I2H 20 4 3 16 320 1 4 0 445 7 GB G20 I2H 20 4 3 16 320 1 4 0 445 8 PT G20 I2H 20 4 3 16 320 1 4 0 445 9 ES G20 I2H 20 4 3 16 320 1 4 0 445 10 DK G20 I2H 20 4 3 16 320 1 4 0...

Page 14: ...co te worden toegezonden aan Wanders Metaalproducten b v Amtweg 4 7077 AL Netterden Storingen welke zijn ontstaan door onoordeelkundig gebruik niet juiste nale ving van de installatie en gebruiksvoors...

Page 15: ...15 BRANDERSET BUITENMANTEL SCHUIFPLAAT GLASRAAM SIERLIJST VERBRANDINGSKAMER...

Page 16: ...16...

Page 17: ...17 INSTALLATION AND OPERATION INSTRUCTIONS FOR BORDEAUX GAS INSET STOVE...

Page 18: ...2 CHIMNEY REQUIREMENTS 2 3 INSTALLATION OF THE STOVE 2 4 FITTING THE FLUE 2 5 FITTING THE GAS PIPE 2 6 VENTILATION 2 7 TTB SAFETY DEVICE 2 8 MAINTENANCE 2 9 FITTING THE LOG SET 2 9A LOG LAYOUT NATURA...

Page 19: ...S G20 I2H C INPUT 4 3kw D OUTPUT MAX 3 5kw E OUTPUT MIN 2 7kw F EFFICIENCY 81 nett G PRESSURE STANDING 20mbar H PRESSURE OPERATING 16mbar I CONSUMPTION MAX 0 445m3 hr J NOZZLE CODE No 320 K LOW FLAME...

Page 20: ...cation Check whether the fireplace is suitable for the type of gas Check burner for proper gas type this is indicated on the data plate Check ventilation requirements the air needed for the combustion...

Page 21: ...nt lift in windy conditions eliminate downdraught and stop rain and other foreign bodies entering the flue 2 3 Installation of the fire Remove the packaging carefully Inspect the fire for any signs of...

Page 22: ...not be able to enter back into the property and therefore the fire must be sealed into the chimney opening complying with the standard in force at that time A flexible flue may need to be fitted For t...

Page 23: ...structions that should be filled out each time the appliance is serviced The service should include the burner unit the pilot flame failure device and the combustion chamber The ceramic logs should al...

Page 24: ...re 2 9A Fitting the Log set natural gas 1 Firstly fill the burner plate with the enclosed vermiculite chips check fig 4a A thin level layer is ideal Caution never use more grains than the supplied amo...

Page 25: ...25 FIG 4b FIG 4C LOG LAYOUT FOR NATURAL GAS FIG 4A FIG 4B FIG 4A...

Page 26: ...S Ultrasound Transmission Range 1 10m 3 33ft Frequency ON 40 5kHz OFF 40kHz Ambient Temperature Transmitter Receiver max 60 C 140 F Connecting Cables max 180 C 356 F Batteries required Handset 1 x 9V...

Page 27: ...d to set the hours The button will set the minutes To return to manual operation you need to wait several seconds or push the TIMER button SETTING THE DESIRED AUTOMATIC TEMPERATURE Press the AUTO butt...

Page 28: ...automatically at the times set If the timer mode is switched on temperature control is done in the same way as in the AUTO mode As soon as the heating cycle off time is reached the Stealth will switch...

Page 29: ...he ignition button pressed for at least 15 seconds then let it go The pilot flame should still be burning 6 Now turn button A further anti clockwise this opens the valve and allows operation of knob B...

Page 30: ...when the glass window is broken or when the door is open The fireplace may only be repaired using original parts supplied by the manufacturer and repairs may only be done by an authorised fitter You...

Page 31: ...31 EXPLODED VIEW OF STOVE COMPONENTS FLUE ADAPTOR OUTER CASING COMBUSTION CHAMBER BURNER ASSEMBLY DECORATIVE FRAME GLASS WINDOW...

Page 32: ...32 TECHNICAL DRAWING 14...

Page 33: ...ENGINEER COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER COMPANY NAME C...

Page 34: ...s __________ Overall length of flue __________ Is there any spillage __________Is the draught excessive __________ Is there any permanent ventilation in the room __________ Has the room double glazing...

Page 35: ...out by the purchaser or any third party not authorised by us or the appliance has been misused or accidentally damaged or damage is due to fair wear and tear or the appliance or defective component s...

Page 36: ...36 Ink 00 7066 Wanders METAALPRODUCTEN B V AMTWEG 4 7077 AL Netterden NL Tel 31 0 315 386414 Fax 31 0 315 386201 e mail info wanders nl www wanders com...