2. Placing
2.1 Prescriptions
For installation and for connection of flue, the requirements of the Fire Regulations
(FeuVO in Germany) apply, as well as local building regulations such as the follow-
ing technical standards DIN 18896, DIN 4705, EN 13384, DIN 18160,
EN 1856-2 and EN 15287. In order for the stove to function correctly the chimney to
which you want to connect the stove must be in good condition.
2.2 Place of installation
The stove draws the air required for burning from the surrounding room. You must
ensure that sufficient air can be drawn in through non-sealed windows and outside
doors. In addition you must ensure that a room volume/heat capacity ratio of at
least 4 m³ per kW nominal heat capacity is available. If the volume is less than this,
then air vents can be used to provide access to further air supply in other rooms
(connecting vents min. 150 cm²).
2.3 Distances
All the combustible materials, furniture or e.g. decoration materials that are in the
close environment of the fireplace should be protected from the heat.
Furnishing in the radiation area
Keep a minimal distance of
80
/
100 cm
(table3) between the front edge of the fire-
place and the combustible equipment, furniture or e.g. decoration materials in the
building. The security distance can be reduced to
40/50 cm
if a heat shield is
placed in front of the object to be protected.
Furnishing beyond the radiation area
The walls beside and behind the fireplace may not be made of combustible
materials, and they cannot be covered with such materials if the distance
on the
sides and back sides under the values on Table 3 is
.
Safety distance to combustible material:
Typ
back
side
front
Typ 109 65 RH6F 6kW
25 cm
45 cm
100 cm
Typ 109 85 RH8F 8kW
30 cm
50 cm
100 cm
Typ 10985 RH8F Automatic 8kW
30 cm
30 cm
80 cm
Table 3
Floor in front of and under the fireplace
Floors made from combustible materials, such as carpets, parquet floors or cork is
to be protected by a shield of non-combustible material – for example ceramics,
stone, glass or steel – placed under the fireplace so that it should reach out to
50 cm
in front and
30 cm
besides.
Summary of Contents for 10965
Page 13: ...13 ...
Page 16: ...16 Bild 1 RH6F 6kW Bild 2 RH8F 8kW Bild 3 RH8F Automatic 8kW RH6F 6kW RH8F 8kW RH8F Automatic ...
Page 17: ...17 Bild 9 Bild 10 Bild 11 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 24: ...24 ...
Page 39: ...39 pic 9 pic 10 pic 11 ...
Page 55: ...55 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 ...
Page 74: ...74 Fig 1 RH6F 6KW Fig 2 RH8F 8KW Fig 3 RH8F Automatic NS RH6F 6kW RH8F 8kW RH8F Automatic NS ...
Page 75: ...75 Fig 12 Fig 13 Fig 14 Fig 9 Fig 10 Fig 11 ...