28
1.2 Installation
Fuels
The equipment can be used with fuels detailed in the followings. This way the “low-
smoke” and trouble-free operation can be secured. Use only dry wood with mois-
ture of maximum 20% and lignite briquette.
Types of fuels
Heating value appr.
kWh/kg
Hard wood
Soft wood
Wood briquette after DIN 51731
Brown-coal
4,0 – 4,2
4,3 – 4,5
5,0 – 5,2
5,3 – 5,5
Filling quantities RH6F 6kW
Filling quantities RH8F 8kW
- Split billet: max. Length: 33 cm
- Split billet: max. Length: 33 cm
max. two billets per filling, appr. 1.4 kg
max. two billets per filling, appr. 1.9 kg
- Lignite briquette: max. 1.5 kg
- Lignite briquette: max. 2.2 kg
Filling quantities RH8F Automatic 8kW
- Split billet: max. Length: 33 cm max. two billets per filling, appr. 1.9 kg
NWL endurance burning, lignite briquettes max. put in 8.2 kg (15 pcs.) on glowing em-
bers, max. 8.2 kg / 4h
Adjustment of the burning air:
Fuel
primary air
regulator
RH6F/ RH8F
Setting of the
fuel selector
All types
primary air
regulator
RH8F Auto-
matic
door down
backside
door down
Warming up, kindling
III
H
Pic. “C”
Wood
Nominal heat-
ing perform-
ance
I
H
Pic. “B”
Browncoal
Nominal heat-
ing perform-
ance
II
K
Pic. “C”
Slow-burning
-
K
Pic. “A”
Putting out of working
order
0
K
Pic. “A”
Wood
Cooking
III
H
-
Browncoal
K
-
Table 1
Summary of Contents for 10965
Page 13: ...13 ...
Page 16: ...16 Bild 1 RH6F 6kW Bild 2 RH8F 8kW Bild 3 RH8F Automatic 8kW RH6F 6kW RH8F 8kW RH8F Automatic ...
Page 17: ...17 Bild 9 Bild 10 Bild 11 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 24: ...24 ...
Page 39: ...39 pic 9 pic 10 pic 11 ...
Page 55: ...55 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 ...
Page 74: ...74 Fig 1 RH6F 6KW Fig 2 RH8F 8KW Fig 3 RH8F Automatic NS RH6F 6kW RH8F 8kW RH8F Automatic NS ...
Page 75: ...75 Fig 12 Fig 13 Fig 14 Fig 9 Fig 10 Fig 11 ...