6.0 INFORMATION REGARDING USE
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
42
6.1 Production start-up
%HIRUHVWDUWLQJXSWKH¿OWHUWKHRSHUDWRULQFKDUJHDQGDXWKRUL]HGIRUWKHSURGXFWLRQPXVWHQVXUHWKDWWKH
safety devices installed are present, in working order and that the operating conditions are respected (hatches
closed, inlet and outlet).
Start-up procedure
Proceed as follows (after preliminary checks):
1)
Start up the dust discharger (if present)
2)
Start up the air compressor.
3)
Start up the control panel (MS LED ON).
4)
Start up the cleaning cycle (clean LED ON)
5)
Check all solenoid valves to ensure they work correctly (the yellow LED goes on when the board sends the
impulse to the solenoid valve)
6)
Check the cleaning cycle duration and the pause time.
)UHTXHQWFKHFNVRIWKH¿OWHURSHUDWLRQ
SDUWLFXODU\GXULQJWKH¿UVWIHZZHHNV
are essential.
Only through these checks it will be possible to determine whether the preset pause duration is the proper one
DVUHJDUGVWKHFOHDQLQJRIWKH¿OWHUFDUWULGJHV
*NQPSUBOU
,QFDVHRIH[FHVVLYHQRLVHVWURQJYLEUDWLRQVHWFVWRSWKH¿OWHUFOHDQLQJV\VWHPDQGUHSRUWWKHSURE
-
OHPWRWKHSHUVRQLQFKDUJHDXWKRUL]HGWRUHVWRUHWKHFRUUHFWZRUNLQJ
Do not use the equipment if damaged.
(TXLSPHQWVKXWGRZQDWWKHHQGRIWKHZRUNF\FOH
1)
6ZLWFK RII WKH ¿OWHU ZLWKRXW GLVFRQQHFWLQJ IURP WKH PDLQV DFFRUGLQJ WR WKH ZLULQJ GLDJUDP LQVWUXFWLRQV
inserted in the panel, the timer is automatically activated for further after-shut-down cleaning cycle of 10
minutes).
2)
After other 10 minutes, disconnect the controller from the mains.
3)
Switch off the compressor.
4)
Switch off the dust discharger valve or screw conveyor (if present).