5
2 TECHNICAL DETAILS
WAMETA PLASMA 40 PFC
Mains voltage(V)
1-phase
,
90VAC-272VAC
Mains frequency HZ
50/60
1-220/230/240±10%
Max input current
(
A
)
22.6
Rated input current
(
KW
)
4.9
Cutting current
(
A
)
20
~
40
Max open circuit voltage
(VDC)
320
Duty cycle
(
40
℃
,
ED
)
50% 40A
60% 36A
100% 30A
Severance cut
(
mm
)
≤25
Recommended cut (mm)
Carbon steel
≤20
Inox
≤20
Aluminium
≤16
Copper
≤12
Measurements
(
mm
)
510*146*278
Protection class
IP23
Insulation class
H
Net weight (kg)
)
8
Cooling
AF
Power factor
0.99
Note: The above information may change as the product is developed.
3 INTRODUCTION
Unpacking:
Make sure that the package contains the items listed on the packing list. Check machine and equipment for transport
damage. If there is obvious damage to the product, please contact the dealer / carrier who delivered the product. Do not connect
damaged equipment to electric network! Connection to mains: the device is connected to a three-phase, grounded electrical network
with 90-272 V / 50-60 Hz protected 16A slow blow fuses. In generator operation, the minimum generator size is 10 kVA.
Pneumatic connection: Plasma cutting is based on the cutting capacity of gas in plasmic form, in this case the air, with the help of a light
arc. Compressed air used for plasma cutting must be oil-free and dry. If necessary, connect an oil and water dissipator to your
compressed air system. Continuous pressure of compressed air at least 4.5 bar and air output at least 100l / min.
4
FRONT AND REAR PANELS AND CONNECTORS
1. Cutting current regulator
2. Machine power indicator
3. Overheat and bring the power indicator light
4. Incorrect torch installation and low air pressure indicator
(1) If the electrode and the cutting tip are short-circuited, the
indicator light is lit and the cutting air is intermittent.
(2) If the electrode or cutting tip is not installed, the indicator light
is on and the cutting air is intermittent.
(3) If the Outside nozzle is not installed properly, the indicator
light will blink.
1
2
3
4
5
6