6.7 Long shut-downs of the device
When the Lump Breaking Feeder Valve has to remain unused for long periods, proceed as described below.
In case the device and/or its components are to be stored and preserved for a certain period of time, in a closed
and dry material at room temperature of (5 -40°C) before re-commissioning them, in order to avoid damages
or deterioration check that the electrical mechanisms and the structure are not damaged; avoid scratching the
painted and finished parts of the equipment.
Before starting the storage operations, coat the structural parts and the surfaces using antioxidant products.
Define and signal those areas where material is being stored.
Danger - Warning
Always use suitable safety personal protection devices (P.P.E.) during all kind of operations.
6.8 Reuse after long shut-down
Important
If the equipment is to be used in different conditions and with materials other than the previous applica
-
tion, ensure the “Permitted use” indications are complied with.
Before reusing the Lump Breaking Feeder Valve after a long shut-down, proceed as described below:
For all fabricated parts:
- remove lubricants or antioxidant protection;
- clear the grease from the coupling bores threading;
- clean the coupling surfaces;
- repair the possible damages the structures might have suffered (corners bent, scratched surfaces, peeled
paint etc.).
As regards the mechanisms:
- check the possible lubricant leakages and replace the worn seals;
- check the proper tightening of the bolted couplings;
- remove lubricants or antioxidant protection;
- remove rust traces from the sliding accessories of the controls;
- lubricate the unpainted mechanical components;
- remove water residues that may be present inside the concave parts of the structure or mechanisms.