NOTE (
*
)
-- Codes are referred to
UN- UNF
threads.
4.
8ESN solenoid control
Complete controls
Direct control by double solenoid with spring return to neutral position, available with emergency manual override.
It’s necessary special spool and standard body (body kit without spool seals).
Due to the large dimension, it’s not possible to assembly more than one control consecutively, except
SD5/2--P
and
SD5/3--P
that
have special bodies with bigger centre--to--centre.
2.
3.
SD5 / 1 -- P (JG3--120) / 1 8ESN LES / AET -- SAE -- 24VDC
Description example:
2.
3.
5.
LES
CAE
4.
1.
2.
Spool options
TYPE
CODE
DESCRIPTION
1(ES)
3CU1210036
Double acting, 3 positions, with A and B
closed in neutral position
2(ES)
3CU1225036
Double acting, 3 positions, with A and B
open to tank in neutral position
3.
Connection kit
TYPE
CODE
DESCRIPTION
8ESN
5V08009
For solenoid joint, with spring return in
neutral position
4.
“B” side options
TYPE
CODE
DESCRIPTION
LES
5LEV105410
Safety lever pivot box for manual
operation
CAE
5COP205100
Endcap
5.
Solenoid
TYPE
CODE
DESCRIPTION
10.5VDC
XSOL314310 Nominal voltage 10.5VDC
12VDC
XSOL314312 Nominal voltage 12VDC
24VDC
XSOL314024 Nominal voltage 24VDC
192VDC
XSOL314192 Nominal voltage 192VDC;
(for 220 VAC supply)
5.
1.
1.
Body kit
*
TYPE
CODE
DESCRIPTION
SD5/1--P
5KC1193100
1 section, standard body
SD5/2--PS
5KC1223003
2 sections, special body
SD5/3--PS
5KC1243006
3 sections, special body
SD5
36
DAT003A