Assembly Instructions 

 Hand Dosing Device WDVHP-0x-HG 

Page 4 of 19 

 

 

 

Walther Systemtechnik GmbH 

 D 76726 Germersheim 

Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91 
http://www.walther-2000.de 

 [email protected] 

 

EC Declaration of Incorporation 

in accordance with EU Machinery Directive 2006/42/EU, dated 17 May 2006, Appendix II B 

We  herewith  confirm  that  the  below  mentioned  incomplete  device  meets  the  basic  requirements  for  safety 
and health as stated in EU Machinery Directive 2006/42/EU for its design and construction as well as for the 
configuration released by us on the market. This machine component will not be operated before it has been 
determined  that  the  incomplete  system  where  the  machine  component  will  be  installed  also  meets  the 
requirements of the Directive (2006/42/EG). 

Manufacturer 

Walther Systemtechnik GmbH 
Hockenheimer Straße 3 
D- 76726 Germersheim 

 

Description  

Hand Dosing Device,  
Article No.  

WDVHP-02-HG 
WDVHP-03-HG  
WDVHP-04-HG  

 

We also declare the conformity with other, product-relevant directives/guidelines: 

 

Mach. Direct. 2006/42/EU App. I, Clause: 1.1.2, 1.1.3, 1.1.5, 1.1.6, 1.3.2, 1.3.3, 
1.3.4, 1.5.9 
EMC- Directive 2014/30/EU, dated 26. February 2014 

 

Applied harmonized standards, in particular: 

DIN EN ISO 12100 

 Safety  of  Machinery 

  General  Design  Principles 

 

Risk  Assessment  and  Risk  Reduction  (ISO 
12100:2010) 

 

In  addition,  we  also  confirm  that  the  special  documentation  according  to  Appendix  VII  Part  B  has 
been prepared. 
 

The manufacturer, respectively his authorized representative obligates himself to submit this documentation 
to the market surveillance authorities, if requested. 
 
This EC Declaration of Incorporation becomes invalid if the incomplete device will be altered or changed 
without consent of Walther Systemtechnik GmbH. 

 
 
Authorized representative for Technical Documentation

 

Stefan Hirl, Hockenheimer Straße 3, D- 76726 Germersheim 
 

 
 
 

Germersheim, 19 April 2016 

(Place, Date) 

 

 

 

 

 

 

 

(Stefan Hirl, Management

 

Summary of Contents for WDVHP-02-HG

Page 1: ...ing volume 0 100 2 000 cm WDVHP 04 HG Dosing volume 1 000 6 000 cm WDVHP 02 HG WDVHP 03 HG WDVHP 04 HG NOTE Please read these Assembly Instructions carefully before first using the device and strictly...

Page 2: ...CTION 7 4 4 TOTAL VIEW DESCRIPTION 8 4 5 CONNECTIONS 8 4 6 TECHNICAL DATA 9 5 INITIAL START UP 10 5 1 MOUNTING AND INSTALLATION 10 5 2 ADJUSTING THE INCOMPLETE DEVICE 10 6 OPERATION 11 6 1 GENERAL INF...

Page 3: ...ng Device WDVHP 0x HG Page 3 of 19 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 3 1 Data Sheet Dos...

Page 4: ...D 76726 Germersheim Description Hand Dosing Device Article No WDVHP 02 HG WDVHP 03 HG WDVHP 04 HG We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 E...

Page 5: ...espective measures of precaution have not been taken This signal word is also used to describe possible property damages IMPORTANT Indicates tips for usage and other particularly useful information No...

Page 6: ...ls etc or media which have not been approved in writing by the manufacturer Using corrosive and or curable materials Operating the device with insufficient knowledge about the operation maintenance an...

Page 7: ...ing Depending on the mode of transportation suitable transport and load securing has to be selected The device will be aligned and leveled by appropriate fastening elements 4 Description of Function 4...

Page 8: ...cription Legend Position Description 1 Regulating sleeve 2 Connection Medium G1 8 3 Outlet Medium M6 4 Connection Control Air M5 5 Trigger Release 6 Handgrip 4 5 Connections IMPORTANT We recommend a m...

Page 9: ...t exceed the max screw in depth Article Number WDVHP 03 HG WDVHP 04 HG Dosing range cm mm 0 100 2 000 100 2000 1 000 6 000 1000 6000 Material inlet mm Internal thread G 1 8 Material outlet mm Internal...

Page 10: ...tage but not mandatory as long 200 bar will not be exceeded IMPORTANT All dosing valves will be thoroughly checked before leaving our factory It is therefore possible that some residues of the test me...

Page 11: ...during operation or altered in its intended purpose function 6 2 Operation Instructions Operating Conditions CAUTION Do not point the jet at people We highly recommend wearing eye protection The spra...

Page 12: ...ption The following has to be observed for a long term interruption of the device No pressure shall be left in system check displays IMPORTANT Please follow the maintenance instructions 7 3 Shutdown o...

Page 13: ...after damage Repair work should only be performed by a specialized technician or the maintenance team or the manufacturer 8 2 Routine Tasks The maintenance intervals below refer to a single shift oper...

Page 14: ...Check the ventilating screws in the supply pump see operating manual of pump Leakage Check dosing valve Leakage at control boring Defective sealing Exchange sealing Permanent signal from sensor Defec...

Page 15: ...WDVHP 0x HG Page 15 of 19 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 Appendix 10 1 Dimensioned...

Page 16: ...for grip 1 4 WDVHP 02 HG E003 Handgrip 1 5 WDVHP 02 HG E005 Control valve 1 6 WDVHP 02 HG E006 Release 1 7 WDVHP 02 HG E007 Switching sleeve 1 8 2000089 0000 O Ring 7 9 LDH0131 O Ring 2 10 LDH0098 O R...

Page 17: ...evice WDVHP 0x HG Page 17 of 19 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 2 Dimensioned and Spa...

Page 18: ...ndrical pin 2 18 ISO8734 4x22A Cylindrical pin 2 19 DIN7984M4x14 Cylinder head screw 1 20 DIN912M3x10 Cylinder head screw 4 21 DIN912 M2 5x10 Cylinder head screw 4 22 970001525 Slot nut for WDV Dosing...

Page 19: ...lefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 3 Accessories Picture Article Number Description WDV DS Dosing Piston Sensor see also Product Catalog...