background image

Rev. 1.4

 

Assembly Instructions - Micro Point Pulse Valve MPP-SPEED 

Page 1 of 17 

 

 

 

Walther Systemtechnik GmbH 

– D 76726 Germersheim 

Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91 
http://www.walther-2000.de 

– [email protected] 

 

Assembly Instructions 

Micro Point Pulse Valve MPP-Speed 

Article number: 

MPP-SPEED 

 
 
 
 

 

 

Pic.: MPP- Speed with medium connector (high-pressure hose)

 

 
 
 
 
 
 

 

NOTE 

Please read the Assembly Instructions carefully before first using the incomplete device and 
strictly adhere to the instructions!  
 
The incomplete device may only be worked with and worked on by persons who are familiar 
with the assembly instructions and the current regulations for industrial safety and accident 
prevention. 

 

Always keep a translated version of the original Assembly Instructions at the incomplete device! 

The assembly instructions have to be close at hand any time! 

 
 
 

Summary of Contents for MPP-SPEED

Page 1: ...medium connector high pressure hose NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions The incomplete device may onl...

Page 2: ...CRIPTION 6 4 1 FUNCTIONAL PRINCIPLE 6 4 2 TECHNICAL DATA OF INCOMPLETE DEVICE 7 4 3 STRESS TEST 7 4 4 TYPE LABEL 8 5 INSTALLATION AND INITIAL START UP 8 5 1 HOSE CONNECTION 8 5 2 INTERFACES 8 5 3 ELEC...

Page 3: ...D 76726 Germersheim Description Micro Point Pulse Valve MPP Speed article No MPP SPEED We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Cla...

Page 4: ...to describe possible property damages IMPORTANT Indicates tips for usage and other particularly useful information No dangerous situation 2 Safety 2 1 General Information The construction of this dev...

Page 5: ...t may hamper its safety without the prior consent of Walther Systemtechnik GmbH Operating the device with defective safety installations or not properly attached or malfunctioning safety devices Using...

Page 6: ...ppropriate fastening elements 4 Functional Description The MPP Speed Micro Point Pulse Valve is an incomplete electrically controlled application device de signed for the application of materials such...

Page 7: ...p to 400 Min control time s 400 Repetition accuracy CV 5 Minimal grid width mm 6 Dosable media greases oils paint UV glue others upon request Energy supply Voltage VDC 24 Power consumption heating W 1...

Page 8: ...e installed in any position The distance to the surface to be applied with the medium depends on the spray pattern Vibrations of the valve caused by fast intermitting cycles require solid and tight in...

Page 9: ...ow the safety instructions on the container or the safety data sheet for the fluid According to the individual application up to 400 tacts per second can be reached under appropriate operating conditi...

Page 10: ...the safety regulations of the trade association must always be observed In order to keep the heat development for the little opening times of the MPP Speed at a minimum and to avoid overheating of th...

Page 11: ...shutdown of the system device Clean pulse valve with a special thinner IMPORTANT Please follow maintenance instructions 8 Maintenance and Repair 8 1 General The MPP Speed Micro Point Pulse Valves are...

Page 12: ...solvents Rinsing with solvents will remove dried contamination from the nozzle The effect can be enhanced by simultaneously increasing the pulse frequency Ultra sonic bath Heavy contamination in the n...

Page 13: ...de 9 Troubleshooting 9 1 General information IMPORTANT First check all supply lines for connection and serviceability In case of serious problems that cannot be resolved please contact the Walther Sys...

Page 14: ...s Micro Point Pulse Valve MPP SPEED Page 14 of 17 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 App...

Page 15: ...1 02 979617 E01 002 1 Lid 1 03 4 Cylinder head stud screw 1 04 979617 E01 003 1 Sticker 1 05 4 Counter sunk screw 1 06 1 Heating foil 1 07 1 Coil 1 08 1 Foil thermometer 1 09 1 Plug 1 10 1 O ring 1 11...

Page 16: ...crew Plug in connection high pressure x Straight screw Plug in connection PA 6 4 x Cartridge connection with Luer Lock adapter x Cable length 5 m x ohne Kabel without cable x 10 3 Accessories Picture...

Page 17: ...info walther 2000 de WLS SPEED H R 01Z001 Holder with fiber optic cables for WLS SPEED H R 01 Please note The use of Walther Light Barriers requires centering recesses on the valves 10 3 1 WALTHER Li...

Reviews: