6.3  Electrical Controls  

The MPP-Speed pulsing valve works with a voltage of 24V DC and a material pressure of up to 50 bar. The 
pulse valve is controlled via a control module  (WLVC) (available as an accessory). ). To obtain a consistent 
application pattern, the material supply must be kept constant. 
 
 

 

Important 

If high material  pressures  are required,  the safety regulations of the trade association 

must always

 be observed.   

 
 
In order  to keep  the  heat  development  for  the  little  opening  times  of  the  MPP  Speed  at  a  minimum  and  to 
avoid  overheating  of  the  solenoid  coil,  controlling  is  done  via  the 

“Peak- and Hold-“procedure. The pulsing 

valve is precisely opened with a temporarily increased  peak current. After opening, a low holding current is 
enough to keep the valve open. Due to the very small opening times and the 

“Peak- and Hold-Function“, it is 

necessary to additionally integrate the WLVC control (if the existing control cannot fulfill this function). 

 

 

 

CAUTION 

The “Peak- and Hold-Function“ must be used for all MPP-Speed valves. Otherwise, the 
valve coil overheats and is destroyed. 
 

(Impulse time = 400µs Holding voltage in % = 12)

 

 

Summary of Contents for MPP-SPEED

Page 1: ...medium connector high pressure hose NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions The incomplete device may onl...

Page 2: ...CRIPTION 6 4 1 FUNCTIONAL PRINCIPLE 6 4 2 TECHNICAL DATA OF INCOMPLETE DEVICE 7 4 3 STRESS TEST 7 4 4 TYPE LABEL 8 5 INSTALLATION AND INITIAL START UP 8 5 1 HOSE CONNECTION 8 5 2 INTERFACES 8 5 3 ELEC...

Page 3: ...D 76726 Germersheim Description Micro Point Pulse Valve MPP Speed article No MPP SPEED We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Cla...

Page 4: ...to describe possible property damages IMPORTANT Indicates tips for usage and other particularly useful information No dangerous situation 2 Safety 2 1 General Information The construction of this dev...

Page 5: ...t may hamper its safety without the prior consent of Walther Systemtechnik GmbH Operating the device with defective safety installations or not properly attached or malfunctioning safety devices Using...

Page 6: ...ppropriate fastening elements 4 Functional Description The MPP Speed Micro Point Pulse Valve is an incomplete electrically controlled application device de signed for the application of materials such...

Page 7: ...p to 400 Min control time s 400 Repetition accuracy CV 5 Minimal grid width mm 6 Dosable media greases oils paint UV glue others upon request Energy supply Voltage VDC 24 Power consumption heating W 1...

Page 8: ...e installed in any position The distance to the surface to be applied with the medium depends on the spray pattern Vibrations of the valve caused by fast intermitting cycles require solid and tight in...

Page 9: ...ow the safety instructions on the container or the safety data sheet for the fluid According to the individual application up to 400 tacts per second can be reached under appropriate operating conditi...

Page 10: ...the safety regulations of the trade association must always be observed In order to keep the heat development for the little opening times of the MPP Speed at a minimum and to avoid overheating of th...

Page 11: ...shutdown of the system device Clean pulse valve with a special thinner IMPORTANT Please follow maintenance instructions 8 Maintenance and Repair 8 1 General The MPP Speed Micro Point Pulse Valves are...

Page 12: ...solvents Rinsing with solvents will remove dried contamination from the nozzle The effect can be enhanced by simultaneously increasing the pulse frequency Ultra sonic bath Heavy contamination in the n...

Page 13: ...de 9 Troubleshooting 9 1 General information IMPORTANT First check all supply lines for connection and serviceability In case of serious problems that cannot be resolved please contact the Walther Sys...

Page 14: ...s Micro Point Pulse Valve MPP SPEED Page 14 of 17 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 App...

Page 15: ...1 02 979617 E01 002 1 Lid 1 03 4 Cylinder head stud screw 1 04 979617 E01 003 1 Sticker 1 05 4 Counter sunk screw 1 06 1 Heating foil 1 07 1 Coil 1 08 1 Foil thermometer 1 09 1 Plug 1 10 1 O ring 1 11...

Page 16: ...crew Plug in connection high pressure x Straight screw Plug in connection PA 6 4 x Cartridge connection with Luer Lock adapter x Cable length 5 m x ohne Kabel without cable x 10 3 Accessories Picture...

Page 17: ...info walther 2000 de WLS SPEED H R 01Z001 Holder with fiber optic cables for WLS SPEED H R 01 Please note The use of Walther Light Barriers requires centering recesses on the valves 10 3 1 WALTHER Li...

Reviews: