Troubleshooting
80
EN
Problem
Cause
Resolving the problem
The generator
does not start.
There is no petrol in
the tank.
Fill the tank with petrol (see
chapter "Filling the tank with
petrol").
The Petrol cock is
closed.
Open the Petrol cock (see chapter
"Starting the power generator").
The petrol supply is
disrupted.
Contact a qualified technician.
The automatic oil
shut-off system
is preventing the
generator from
starting.
Check the engine oil level (see
chapter "Checking the engine oil
level").
The spark plug is
dirty or worn out.
Clean the spark plug or replace
it (see chapter "Cleaning and
replacing the spark plug").
The air filter is dirty.
Clean the air filters (see chapter
"Cleaning the air filter").
The power generator
is faulty.
Contact the manufacturer at the
service address mentioned on the
warranty card or a technician.
The generator
supplies no or too
little voltage.
The Eco mode is
switched on.
Press the Eco switch on the right
side to the "MAX" position (see
chapter "Eco mode").
The air filter is dirty.
Clean the air filters (see chapter
"Cleaning the air filter").
The power generator
is faulty.
Contact the manufacturer at the
service address mentioned on the
warranty card or a technician.
Unusual noises,
vibrations or smells
are observed
when the power
generator is
running.
The power generator
is faulty.
Contact the manufacturer at the
service address mentioned on the
warranty card or a technician.
Troubleshooting
Summary of Contents for WWS-IGS1000
Page 37: ...Explosionszeichnung 37 DE Explosionszeichnung...
Page 44: ...44...
Page 79: ...Exploded view 79 EN Exploded view...
Page 86: ...86...
Page 123: ...Vue clat e 123 FR Vue clat e...
Page 130: ...130...
Page 166: ...V kres d l 166 CZ V kres d l...
Page 208: ...Razstavljena risba sestavnih delov 208 SI Razstavljena risba sestavnih delov...
Page 215: ......