9
ACCUDRILL
TM
(should ACCUDRILL
TM
fail to operate) the operator is required to press the start button
twice to re-activate the machine.
•
Always switch off the motor by depressing the green start/stop button or blue button depending
upon operation. Do not switch off the motor by pressing the magnet switch.
•
Apply light pressure when commencing the cut of a hole until the cutter is introduced into the work
surface. Pressure can then be increased sufficiently to load the motor. Excessive pressure is
undesirable, it does not increase the speed of penetration and will cause the safety overload
protection device to stop the motor (the motor can be restarted by operating the motor start
button) and may cause excessive heat which may result in inconsistent slug ejection
•
Always ensure that the slug has been ejected from the previous hole before commencing to cut the
next.
•
If the slug sticks in the cutter, move the machine to a flat surface, switch on the magnet and gently
bring the cutter down to make contact with the surface. This will usually straighten a cocked slug
and allow it to eject normally.
•
Apply a small amount of light oil lubricant regularly to the slide.
•
Cutter breakage is usually caused by insecure anchorage or a loosely fitting slide (Refer to routine
maintenance instructions).
•
Only use approved cutting fluid. Walter cutting fluid has been specially formulated to maximise the
cutters performance.
Summary of Contents for ICECUT 250 Auto
Page 1: ...ICECUTTM 250 Auto Magnetic Drilling Unit 39 D 252 120V This Machine is CSA UL certified...
Page 21: ...21...
Page 22: ...22 ICECUTTM 250 Auto Perceuse base magn tique 39 D 252 120V Cette machine est certifi e CSA...
Page 50: ...50 7A OPERACI N DEL PANEL DE CONTROL...
Page 63: ...63...
Page 64: ...64...
Page 71: ...71...