6. Installation
6.a. Levelling of the wood-gasification stove
Please level off the stove with the help of a spirit level.
6.b. Different connections
6.b.1. Electricity connection
Please connect the thermostat, which was delivered together with the stove, with the
heating pump and through a plug with the electric cable.
The Thermostat needs to be set to at least 60°C!
Inside the thermostat there are 4 connections. You need to connect the junctions C and 2
as well as the ground! The connector 1 remains unused! If you use the WAL02, it is not
necessary to connect the thermostat!