background image

 

 

   

 

 

Revision 5 

15 

Product Manual  
WHBV-101W-LH-NB and WHBV-101W-RH-NB 

 

WARNING! The washbasin weighs approximately 35Kg. Always use safe lifting 
procedures when lifting heavy loads. Make sure the washbasin is correctly 
secured to the wall or correctly supported before working in the vicinity. 

 

NOTE: Make sure you do not abrade or damage water tubes & waste pipe when 
you insert them through the wall. 

 

5.5 Water and Waste Connections 

 

NOTE: The connection of the water supply and waste must be completed in 
accordance with the plumbing code AS/NZS 3500 
 
NOTE: Before you carry out the following steps, flush the water supply pipes to 
remove any debris and trapped air. 
 
NOTE: Fit a Y strainer in the water supply feed pipe before connection to the 
washbasin, especially on older installations where loose particles from ageing 
water pipes can cause a blockage.  
 
NOTE: Fit a service isolating tap on the water supply feed. This allows for ease 
of 

maintenance when required. The isolating tap is not supplied with the 

product and should be purchased separately. 

 
NOTE: Use of any pipe sealing compound should be avoided to prevent 
blockages & damage to the basin faucet. 

 
1.  Complete the connection of the water supply to the basin tap outlet. 

 

2.  Connect the waste pipe adapter to a deep seal waste trap. 

 

NOTE: The trap must be fitted at a lower height than the basin waste pipe for 
correct drainage. Fit an elbow connector to the waste pipe first before 
dropping down to the trap inlet connection. 
 
 
 
 
 
 

Summary of Contents for WHBV-101W-LH-NB

Page 1: ...Product Manual WHBV 101W LH NB and WHBV 101W RH NB Washbasin with Integral Tap...

Page 2: ...Revision 5 2 Product Manual WHBV 101W LH NB and WHBV 101W RH NB...

Page 3: ...2 5 Menu items 5 3 Glossary 6 4 Overview 6 5 Installation and Commissioning 7 5 1 Package Contents 7 5 2 Site Preparation 7 5 2 1 Mounting Guidelines 7 5 3 Preparing the Washbasin 12 5 4 Mounting the...

Page 4: ...NZS 3500 the PCA and your local regulatory requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provis...

Page 5: ...ngs before you install and commission the wash basin Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is us...

Page 6: ...r anti ligature products have been designed to reduce the likelihood of a ligature attachment however it is the responsibility of the purchaser or service provider to ensure it is risk assessed and su...

Page 7: ...ation 5 2 Site Preparation 5 2 1 Mounting Guidelines The washbasin must be attached to a vertical surface that can support the weight of the washbasin See Table 1 on page 16 for the weight Refer to Fi...

Page 8: ...Revision 5 8 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 1 WHBV 101W RH NB Basin Details...

Page 9: ...Revision 5 9 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 2 WHBV 101W LH NB Basin Details...

Page 10: ...Revision 5 10 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 3 Wall hole sizes positioning for WHBV 101W RH NB...

Page 11: ...Revision 5 11 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 4 Wall hole sizes positioning for WHBV 101W LH NB...

Page 12: ...aptor Item 8 figure 5 into the integral push fit connection on the basin inlet and attach a water supply pipe The water supply connection is provided on site by others Site conditions and the type of...

Page 13: ...Revision 5 13 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 5 Components and assembly details for the WHBV 101W RH NB...

Page 14: ...pective holes in the brackets Item 2 figure 5 3 Once the positions have been checked make sure the basin seats flush against the wall The side support angle brackets Item 2 figure 5 can be adjusted fo...

Page 15: ...ebris and trapped air NOTE Fit a Y strainer in the water supply feed pipe before connection to the washbasin especially on older installations where loose particles from ageing water pipes can cause a...

Page 16: ...rged from the system and to ensure that the flow rate is correct 5 7 Technical Specifications Table 1 Technical specifications Weight Approximately 35Kg Dimensions 720mm W x 310mm H x 440mm D Water Su...

Page 17: ...n be obtained from our customer service department 6 1 Maintenance General wear mainly affects the components in contact with water If the unit is installed in a hard water area lime scale may need to...

Page 18: ...the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the M...

Page 19: ...el 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com Galvin Engineering Pty Ltd 410 Victoria Road Malaga Western Australia 6090 Australia tel 61 8 9338 2344 fax 61...

Reviews: