background image

 

 

   

 

 

Revision 5 

Product Manual  
WHBV-101W-LH-NB and WHBV-101W-RH-NB 

 

 

1. Disclaimer 

 

Every effort has been made to supply information within this manual which is correct.  
Wallgate Limited and Galvin Engineering will not be liable for any damage or loss 
that arises if the person installing, operating, or maintaining the unit has not read or 
not complied with the manual.   
  
Wallgate Limited or Galvin Engineering reserves the right to alter, update or improve 
its product specification at any time without prior notice. This manual is specific to the 
product that it has been supplied with at the date of supply.   
  
The product must be installed in accordance with these installation instructions and in 
accordance with AS/NZS 3500, the PCA and your local regulatory requirements. 
Water and/or electrical supply conditions must also comply to the applicable national 
and/or state standards. Failing to comply with these provisions shall void the product 
warranty and may affect the performance of the product. Further installation 
compliance requirements are listed in document 002.90.00.00 – Installation 
Compliance. 
 
No part of this publication and the information contained may be reproduced, 
transmitted, stored in a retrieval system, used or disclosed wholly or partly without 
prior written permission from Wallgate Limited or Galvin Engineering. 
 
Please ensure this manual is passed to the end user.  The manual forms an integral 
part of the product and should be kept for its working life. Additional copies of this 
and other supporting documents are available by contacting Galvin Engineering by 
visiting www.galvinengineering.com.au. 

 
 
 
 
 
 
 
 

Summary of Contents for WHBV-101W-LH-NB

Page 1: ...Product Manual WHBV 101W LH NB and WHBV 101W RH NB Washbasin with Integral Tap...

Page 2: ...Revision 5 2 Product Manual WHBV 101W LH NB and WHBV 101W RH NB...

Page 3: ...2 5 Menu items 5 3 Glossary 6 4 Overview 6 5 Installation and Commissioning 7 5 1 Package Contents 7 5 2 Site Preparation 7 5 2 1 Mounting Guidelines 7 5 3 Preparing the Washbasin 12 5 4 Mounting the...

Page 4: ...NZS 3500 the PCA and your local regulatory requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provis...

Page 5: ...ngs before you install and commission the wash basin Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is us...

Page 6: ...r anti ligature products have been designed to reduce the likelihood of a ligature attachment however it is the responsibility of the purchaser or service provider to ensure it is risk assessed and su...

Page 7: ...ation 5 2 Site Preparation 5 2 1 Mounting Guidelines The washbasin must be attached to a vertical surface that can support the weight of the washbasin See Table 1 on page 16 for the weight Refer to Fi...

Page 8: ...Revision 5 8 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 1 WHBV 101W RH NB Basin Details...

Page 9: ...Revision 5 9 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 2 WHBV 101W LH NB Basin Details...

Page 10: ...Revision 5 10 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 3 Wall hole sizes positioning for WHBV 101W RH NB...

Page 11: ...Revision 5 11 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 4 Wall hole sizes positioning for WHBV 101W LH NB...

Page 12: ...aptor Item 8 figure 5 into the integral push fit connection on the basin inlet and attach a water supply pipe The water supply connection is provided on site by others Site conditions and the type of...

Page 13: ...Revision 5 13 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 5 Components and assembly details for the WHBV 101W RH NB...

Page 14: ...pective holes in the brackets Item 2 figure 5 3 Once the positions have been checked make sure the basin seats flush against the wall The side support angle brackets Item 2 figure 5 can be adjusted fo...

Page 15: ...ebris and trapped air NOTE Fit a Y strainer in the water supply feed pipe before connection to the washbasin especially on older installations where loose particles from ageing water pipes can cause a...

Page 16: ...rged from the system and to ensure that the flow rate is correct 5 7 Technical Specifications Table 1 Technical specifications Weight Approximately 35Kg Dimensions 720mm W x 310mm H x 440mm D Water Su...

Page 17: ...n be obtained from our customer service department 6 1 Maintenance General wear mainly affects the components in contact with water If the unit is installed in a hard water area lime scale may need to...

Page 18: ...the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the M...

Page 19: ...el 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com Galvin Engineering Pty Ltd 410 Victoria Road Malaga Western Australia 6090 Australia tel 61 8 9338 2344 fax 61...

Reviews: