13
Power Supply Unit
The Power Supply unit for Pulsar can be replaced if damaged. The Power Supply unit is enclosed within
the charger’s body and connected to the Power board.
Unscrew the Torx screw at the bottom of
the charger using a Torx T9 screwdriver and
save it for later use.
Carefully remove the communications cable
from the body of the charger.
Turn off the power supply to the charger.
Using the opening tool, unclip the cover from
the charger’s body.
1.
3.
2.
4.
Ensure that the communications cable is detached
gently from connector. Do not pull or apply excessive
force to remove the cable.
Removing the old Power Supply Unit
Remove the cables that are connected to
the Power Supply unit. Use a screwdriver to
release the cables from the connectors
Using a screwdriver remove the power input
and output cables.
5.
6.
Summary of Contents for PULSAR