wallbe GmbH – Paderborner Str. 76 – 33189 Schlangen
Tel: +49 5252 989440 Mail: [email protected]
22
4.0 Technical details: wallbe Pro
Technical details
Model
wallbe Pro
3,7kW
wallbe Pro
4,6kW
wallbe Pro
7,4kW
wallbe Pro 11kW wallbe Pro 22kW
Dimensions in
mm (h x w x d)
350x350x170
350x350x170
350x350x170
350x350x170
350x350x170
Weight
Ca. 12 kg
Ca. 12 kg
Ca. 12 kg
Ca. 12 kg
Ca. 12 kg
Temp. rating
-25 to +70°C
-25 to +70°C
-25 to +70°C
-25 to +70°C
-25 to +70°C
IP-Class
IP54
IP54
IP54
IP54
IP54
Chargepoint
230V/1P/20A
Standard:
Type 2 socket
or
cable
Type 2 or Type 1
Optional:
Schuko socket
230V/1P/20A
Standard:
Type 2 socket
or
cable
Type 2 or Type 1
Optional:
Schuko socket
230V/1P/32A
Standard:
Type 2 socket
or
cable
Type 2 or Type 1
Optional:
Schuko socket
400V/3P/20A
Standard:
Type 2 socket
or
cable
Type 2 or Type 1
Optional:
Schuko socket
400V/3P/32A
Standard:
Type 2 socket
or
cable
Type 2 or Type 1
Optional:
Schuko socket
Compliance
Mode 3
IEC61851
Mode 3
IEC61851
Mode 3
IEC61851
Mode 3
IEC61851
Mode 3
IEC61851
Load contactor
2pol. 25A
2pol. 25A
2pol.40A
4pol. 25A
4pol. 40A
Control fuse
1pol.B6
1pol.B6
1pol.B6
1pol.B6
1pol.B6
Integrated
safety measures
1. RCM module:
DC detection
<6mA
2. Lock & Release
module
3. Contactor
welding
detection
1. RCM module:
DC detection
<6mA
2. Lock & Release
module
3. Contactor
welding
detection
1. RCM module:
DC detection
<6mA
2. Lock & Release
module
3. Contactor
welding
detection
1. RCM module:
DC detection
<6mA
2. Lock & Release
module
3. Contactor
welding
detection
1. RCM module:
DC detection
<6mA
2. Lock & Release
module
3. Contactor
welding
detection
RCD
Mandatory in
switch board:
RCD Type A
0,03A/25A
Mandatory in
switch board:
RCD Type A
0,03A/25A
Mandatory in
switch board:
RCD Type A
0,03A/40A
Mandatory in
switch board:
RCD Type A
0,03A/25A
Mandatory in
switch board:
RCD Type A
0,03A/40A
LS-switch
Not integrated
Not integrated
Not integrated
Not integrated
Not integrated
Authorization
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External apProval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External apProval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External apProval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External apProval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External apProval
Case lockable
Yes (optional)
Yes (optional)
Yes (optional)
Yes (optional)
Yes (optional)
Energymeter
Yes (optional)
Yes (optional)
Yes (optional)
Yes (optional)
Yes (optional)
Protocols
Modbus
Modbus
Modbus
Modbus
Modbus
Interfaces
RS485
Ethernet RJ45
RS485
Ethernet RJ45
RS485
Ethernet RJ45
RS485
Ethernet RJ45
RS485
Ethernet RJ45