Spartan
- 26 -
Fixed tank connection 30011
Installation instructions for Tank connection 30011
You will need to make a Ø 25 mm (1") hole in the upper surface of the fuel tank. Choose the location of the hole
so that when the fuel tank tilts the end of the intake pipe will stay in the fuel even if the tank is not full. If the end
of the intake pipe does not reach the fuel, the device will quickly choke on the air in the fuel system.
Cut the fuel intake pipe (Ø 3.17/0.8 mm) to the appropriate length. The end of the pipe must not touch the
bottom of the tank in order to keep water and sediment from the system. It is recommended to cut the pipe short
enough to leave the engine intake pipe at a lower level. This way the device cannot empty the tank.
Install the pipe straight end first and angle the two "ears" below the threaded barrel inside the hole and then
align the threaded barrel vertically so the ears are hooked on the underside of the tank top. Carefully slip the
rubber washer over the bent pipe end and over the threaded barrel, followed by the metal washer and the nut.
Thread the nut to the threaded barrel and tighten, sealing the fitting to the top surface of the tank.