background image

HEATING WITH BLOWER LID

(STOVES WITH BLOWER LID)

Once the stove is fully ignited, lower the blower lid down
until it locks and the device will begin to blow warm air
for heating. 

When the PI Thermo Mode is chosen,
the orange thermostat/blower lid light
is on. 

Rotate the 

Temperature/Power Knob

 to the

desired temperature (refer to temperature
chart on the first page) or heating power.

Switch between modes by turning the

Temperature/Power Knob

 back and

forth to min - max - min. 

To switch back to cooking, unlock the lid and push
it back to upward position. Make sure the stove is
in Manual Mode before cooking. 

Stove does not operate correctly if it is left in
PI Thermo Mode.

In Manual Mode, the light is off.

PI Thermo Mode:

 Set a target temperature (C°/F°) 

Manual Mode:

 Control heating power with knob 

Heating on

30 s

30 s

Combustion has begun/is running

Set temperature on heater is higher than

cabin temperature - power is increasing

Set temperature on heater is lower than

cabin temperature - power is decreasing

Locked for security

The device locks itself 

after two unsuccessful starts 

Sun Switch has shut down the device  

Cooldown/Flameout

I

Heating on in High Altitude Mode

I

Overheat

I

Reminder indicating there was a fault

after fault code flashed for 5 min 

30 s

www.wallas.com

If the unit has locked itself,
the combustion light and the
heating indicator light will
flash signaling there has been
a failure that should be
investigated and resolved
prior to further use. Lights
will flash for about 5 min.

1) While the lights are still
flashing, switch the main
power off from the battery
(Pull power plug, remove the
fuse, open breakers, or in-line
switch). 

2) Wait for 5 sec. and switch
the main power back on.

3) Press Heat Button (3) for
more than 3 seconds to shut
down the heater.

4) Restart the heater
normally. 
 

UNLOCKING THE
UNIT 

Reach Out to a Professional for the Following: 

Glow Failure

2 s

2 s

Combustion Air Blower Fault

2 s

Main Blower Fault

2 s

2 s

I
I

I

Low voltage (usually about 15 sec

after initiating start) 

I

See instructional video

to unlock 

All rights reserved. Wallas-Marin reserves the right to change or improve its products and to

make changes in the content of this guide without obligation to notify any person or organization

of such changes or improvements. Go to www.wallas.com for current updates and supplemental

information concerning the use of this product. 

PANEL LIGHTS 

I