G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 4
7.
Additional inlet connection -
One special 40mm connection with one end as spigot & other end as socket is supplied as
fitting. This need to be used for connecting a WHB or a Sink or any other waste water outlet to pump unit.
Refer photos below
for details.
The extra connection can be purchased from Wallace Pumps if required.
8.
MANUAL RUN / RESET button –
Provided on the pump cover under a clear plastic bubble. Refer figure 2 page 2. Pushing
& holding this button will enable motor to run as long as the button is held push down. In case of alarm trip same button will
reset the trip provided the trip reason is resolved. Exercise extreme care. Call a service agent if the motor continues to trip.
9. A Wallace 32 mm full flow non-clog
swing check valve
with solvent weld ends suitable for PVC pressure pipe is provided as
one of fittings. This should be installed in the delivery pipe in a vertical position within one metre (pipe length) of the unit to
stop backflow of liquid from the pipe back into the collection tank.
10.
Isolating Ball Valve -
A 32 mm full flow Isolating Ball valve with solvent ends suitable for PVC Pressure pipe is supplied for
installation after the 32 mm non-return swing check valve.
11.
Labels -
Labels Warning against
inappropriate dumping of
non-organic products such as condoms, sanitary pads, wet
wipes, tampons, nappies, sand, stones, tar, cement, coarse paper, non-water-soluble paper towels, cardboard, plastic
bags, fat, oil etc. in the toilet, to be affixed to appropriate fixtures & appliances.
Pumping of these products may cause pump unit to malfunction or jam. Any damage to pump or any other property or
person due to such jam is not covered under warranty.
2. TYPICAL WASTE WATER CONNECTION DRAWING WITH SHOWER TRAY/BATH WASTE HEIGHT
Refer below typical connections shown connected to pump unit. If in doubt please call Wallace Pumps for further details.
Shower Tray or Bath Waste Height:
Refer above schematic drawing. When pump & shower and/or bath are in same room, the advised minimum height of the shower
tray waste discharge point is 180 mm above the MULTISAN-PRO floor level. The final height is determined by starting from the
MULTISAN-PRO Bottom inlet connection at 100 mm centreline and work back to the shower tray discharge point at the minimum
pipe fall rate as per building & plumbing code. Add the necessary height for the trap to give you the total height from the floor to
the shower tray.
Pipe Sizes
PAN discharge pipe if direct pan connection
Not required
DRAIN from shower and bath to MULTISAN-PRO special fitting with NRV
40mm Waste Pipe
DRAIN from vanity, W/M, Kitchen sink to MULTISAN-PRO special fitting 40mm Waste Pipe
VENT from MULTISAN-PRO to approved termination (If required)
40mm Waste Pipe
PUMP DELIVERY from MULTISAN-PRO to approved termination
32mm PVC Pressure Pipe