26
Gas Regulator
NOTE: The regulator supplied is convertible between Natural Gas and LPG, but it’s outlet
pressure is fixed ex-factory and is NOT to be adjusted.
1.
Ensure that the gas and electrical supply are turned off.
2.
Unscrew the hexagonal cap (23 mm A/F) from the regulator.
3.
Un-clip the plastic pin from the cap, reverse the pin and re-fit it back
to the cap the correct way for the gas type to be used.
(Either ‘LP’
or ‘NAT’ should be visible on the flank of the pin once
re-fitted to the cap)
.
4.
Screw the cap back into the regulator.
Gas Type Identification Label
On completion of the gas conversion, replace gas type identification labels, located at:-
- The rear of the appliance, above the gas connection.
- beside the rating plate.
Commissioning
Before leaving the converted installation;
1.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with the operating instructions specified in the
“Operation” section of this manual.
•
Light the Pilot Burners.
•
Light the Main Burners.
•
Check the Low Fire burner operation.
•
Check the High Fire burner operation.
•
Ensure that all the controls operate correctly.
•
Ensure that the operating pressure remains correct.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Gas Conversion and Specifications
NOTE, Pin rotated
for Natural Gas
NOTE, Pin
rotated for LPG
Fig 37
Summary of Contents for RNL8510GC
Page 7: ...5 Dimensions RN L 8510GC RN L 8510GC RN L 8513GC Cooktop Options...
Page 8: ...6 Dimensions RN L 8610GC RN L 8610GC RN L 8613GC RN L 8616GC RN L 8619GC Cooktop Options...
Page 9: ...7 Dimensions RN L 8810GC RN L 8810GC RN L 8813GC RN L 8816GC RN L 8819GC Cooktop Options...
Page 33: ...31...