22
Gas Conversion and Specifications
- UK Only:
Category:
II
2H3P.
Flue Type:
A
1.
*
Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to details in this section for information).
Natural Gas (G20)
Propane (G31)
Target Top
Main Burner Injector (Inner Ring)
Ø 1.70 mm
Ø 1.10 mm
Main Burner Injector (Outer Ring)
Ø 2.60 mm
Ø 1.55 mm
Pilot Burner Injector
0.35 0.25
Burner Aeration Screw X (Inner)
25 mm
20 mm
Burner Aeration Screw Y (Outer)
28 mm
25 mm
Low Fire Adjustment
2
1
/
2
turns out (ccw)
1
¾
turn out (ccw)
Oven
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open
Fully Open
Low Fire Screw
Ø 1.5 mm
Ø 0.95 mm
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
9.9 mbar (*)
26.8 mbar (*)
Gas Regulator Cap Screw