Weekly Cleaning 

NOTE: 

• 

If the pasta cooker usage is very high, we recommend that the weekly cleaning  
procedure is carried out on a more frequent basis. 

• 

Ensure that protective gloves are worn during the cleaning process. 

• 

DO NOT use harsh abrasive detergents, strong solvents, sharp scrapers or caustic  
detergents as they will damage the surface of the pasta cooker. 

• 

Ensure that the water circuit is free of ferrous particles.  Any such particles deposited 
in the bottom of the tank may cause it to rust. 

 

Thoroughly clean the interior and exterior of the pasta cooker regularly.  Do not use wire brushes on the 

pan.  Clean using a mild detergent and a hot water solution using soft cloth or a soft bristled brush.  Dry 

the appliance thoroughly using a dry clean cloth. 

 

NOTE:  In order to prevent the forming of rust on the steel components, ensure that the detergent 

or cleaning material has been entirely removed after each cleaning process. 

 

Stainless Steel Surfaces 

a.  Clean the interior and exterior surfaces of the pasta cooker with hot water, a mild detergent  

solution and a soft scrubbing brush.  Note that the gas control knobs are a push fit onto the gas 

and water control valve spindles and can be removed to allow cleaning of the front of the control 

panel. 

b.  Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless 

steel wool.  Always apply cleaner when the appliance is cold and rub in the direction of the grain. 

c.  Dry all components thoroughly with a dry cloth and polish with a soft dry cloth. 
 

Periodic Maintenance 

NOTE:  All maintenance operations should only be carried out by a qualified service person. 
 

To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts 

should be checked and adjusted periodically by a qualified service person.  If any small faults occur, have 
them attended to promptly.  Don't wait until they cause a complete breakdown.  It is recommended that 

the appliance is serviced every 6 months. 
 
If the appliance is not used for long periods, close the gas shut-off valve upstream of the appliance and 

clean the appliance thoroughly. 
 
The appliance should be inspected and the gas exhaust flue cleaned by an authorized service person at 

least every 6 months. 

Cleaning and Maintenance

 

WARNING: 

 

DO NOT ATTEMPT TO MOVE THE PASTA COOKER WHILST THE COOKER IS FULL OF WATER. 

 

BEFORE ATTEMPTING TO MOVE THE PASTA COOKER, ENSURE THAT ALL THE WATER HAS 

BEEN DRAINED FROM THE TANK.  REFER TO THE INFORMATION ON THE PREVIOUS PAGE 

ON HOW TO DRAIN THE WATER FROM THE PASTA COOKER. 

Summary of Contents for PC8140G

Page 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Pasta Cooker PC8140G PCL8140G Date Purchased Serial Number Dealer Service Provider 230008 10 For use in GB IE...

Page 2: ...0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NEW...

Page 3: ...ances Assembly Gas Connection Water Connection Drainage Connection Commissioning Operation 10 Operation Guide Description of Controls Before Use Filling the Tank Lighting the Pilot Burner Lighting the...

Page 4: ...THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED...

Page 5: ...ist for details Plinth Kit Gas Supply Requirements Australia New Zealand Only UK Only Appliance Classification Category II2H3P Flue Type A1 NOTE The burner operating pressure is to be measured at the...

Page 6: ...ional rear connection is available Connection is 3 4 BSP male Water Supply Requirements Cold water connection is 1 2 tube connection via 15 mm crox fitting located 50 mm from the LH side 556 mm from r...

Page 7: ...5 Dimensions PC L 8140G...

Page 8: ...must be carried out by qualified service persons only Failure to install equipment to the relevant codes and manufacturer s specifications shown in this section will void the warranty Components havin...

Page 9: ...In order to facilitate easy operation drainage and servicing of the appliance a minimum of 600 mm clearance should be maintained at the front of the appliance Any gas burning appliance requires adequa...

Page 10: ...e NOTE The gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per the Gas Conversion Section in this manual Ensure the regulator is converted to the corr...

Page 11: ...to exit above the tundish All drain piping must be with materials suitable for conveying boiling water Drain connection is R1 BSP drain overflow Commissioning The following commissioning checks must...

Page 12: ...r and pilot burner and is controlled by a single gas controller with flame failure protection to control both main burner and pilot Open tank design to simplify cleaning operation PC8140G Pasta Cooker...

Page 13: ...water flow out of the water supply nozzle that just causes water to continually flow out of the overflow This method provides Maintained water level for cooking Skimming or flushing effect to prevent...

Page 14: ...ot ignite repeat Items 1 to 6 above Lighting the Main Burner 1 Depress and rotate the gas control knob to the High Flame position the main burner will now ignite automatically off the pilot burner 2 T...

Page 15: ...re that protective gloves are worn during the cleaning process Clean the pan regularly after each use Draining and Cleaning Opening the Drain Valve a Lift the locking slide on valve handle Fig 5 to re...

Page 16: ...brush use a wooden probe to dislodge any obstruction 4 Clean the interior and exterior of the pan regularly at the end of each day Do not use wire brushes on the pan Clean using a mild detergent and a...

Page 17: ...and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cle...

Page 18: ...hecks out satis but the problem still persists The gas control valve is defective and needs replacement Pilot Burner delay in ignition of main burners Check operating pressure as stated in Installatio...

Page 19: ...17 Wiring Schematics PC8140G Pasta Cooker...

Page 20: ...the end of this section Main Burner Injectors 1 Unscrew and remove the main burner injectors 12 7 mm A F located in front of main burner venturi openings 2 Determine the correct injectors for the cor...

Page 21: ...supplied is convertible between Natural Gas and LPG but it s outlet pressure is fixed ex factory and is NOT to be adjusted 1 Ensure that the gas supply is turned OFF at the mains 2 Unscrew the hexago...

Page 22: ...rdance with the operating instructions specified in the Operation section of this manual Light the Pilot Burners Light the Main Burners Check the Thermostat operation Ensure that all the controls oper...

Page 23: ...Refer to the Gas Conversion and Specification Section for further details Natural Gas LP Gas Propane Main Burner Injectors 3 10mm 1 90mm Pilot Burner Injectors 0 62 0 35 Low Fire Screw 1 55mm 2 turns...

Page 24: ...a Cooker Basket 320 x 165mm Optional Accessory 229836 Pasta Cooker Basket 165 x 165mm 229707 Pasta Cooker Basket Drain Tray 229682 Basket Support Frame 227856 Door Magnet 019390 Water Drain Valve 2298...

Page 25: ...23...

Reviews: