3
Specifications
Model Numbers covered in this Specification
GT8600G Gas Griddle Toaster
General
A commercial heavy-duty gas fired griddle toaster, having two tubular burners heating a griddle
plate from underneath and providing toasting heat for the toasting rack below.
Burners are operated by individual control valves and are provided with a piezo ignition permanent
pilot incorporating a thermocouple flame failure control.
Optional Accessories
This appliance can be fitted with the following optional accessories, (refer to the 'Replacement Parts
List' for details).
•
Plinth Kit.
Gas Supply Requirements
- Australia / New Zealand Only:
- UK Only:
NOTE:
* - The burner operating pressure is to be measured at the manifold test point with both burners
operating at full setting. The operating pressure is ex-factory set, through the appliance
regulator and is not to be adjusted, apart from when converting between gases, if required.
(Refer to the ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located 130mm from the right hand side of the appliance, 35mm from
the rear and 654mm from the floor and is entered from beneath the appliance. An optional
underside connection is available.
Connection is ½ BSP male.
Natural Gas
LP Gas (Propane)
Input Rating
(N.H.G.C.)
42 MJ/hr
(39,800 Btu/hr)
Supply Pressure
1.13 - 3.40
kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
Operating Pressure
1.00 kPa (*)
(4.0” w.c.)
2.50 kPa (*)
(10.0” w.c.)
Gas Connection
1
/
2
” BSP Male
42 MJ/hr
(39,800 Btu/hr)
Natural Gas (G20)
Propane (G31)
Heat Input (nett)
Nominal
11.0 kW
11.0 kW
Reduced
6.0 kW
5.6 kW
Gas Rate (nett)
Nominal
1.16 m
3
/hr
0.85 kg/hr
Reduced
0.63 m
3
/hr
0.44 kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
10 mbar (*)
26 mbar (*)
Gas Connection
1
/
2