3
GP[1]8600E - B
Electric Griddle 600mm wide Bench Model.
GP[1]8600E - CB
Electric Griddle 600mm wide with Cabinet Base.
GP[1]8600E - LS
Electric Griddle 600mm wide on Leg Stand.
GP[1]8900E - B
Electric Griddle 900mm wide Bench Model.
GP[1]8900E - CB
Electric Griddle 900mm wide with Cabinet Base.
GP[1]8900E - LS
Electric Griddle 900mm wide on Leg Stand.
GP[1]8900E - RB
Electric Griddle 900mm wide with Refrigerated Base.
GP[1]8120E - B
Electric Griddle 1200mm wide Bench Model.
GP[1]8120E - CB
Electric Griddle 1200mm wide with Cabinet Base.
GP[1]8120E - LS
Electric Griddle 1200mm wide on Leg Stand.
GP[1]8120E - RB
Electric Griddle 1200mm wide with Refrigerated Base.
NOTE:
[1]: - Model Options;
-
- Standard.
L
- Low Back.
B
- Bold Front.
LB
- Low Back and Bold Front.
When connecting a Waldorf electric appliance to the mains supply, ensure that the following is carried out:-
An isolating switch is fitted within 2m of the appliance, but not on the appliance and in such a
position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS 3191
part 2.10.11. or IEC 60245-IEC-57) e.g. H05 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating and
the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance for the
current drawn on that line.
Model
Power Connection
Input Rating
230 - 240 V, 50 / 60 Hz,
1 P+N+E.
7.2 kW,
30 A @ 240 V
GP8600E
380 V, 50 / 60 Hz,
3 P+N+E.
7.2 kW,
L1 - 11.5 Amps
L2 - 11.5 Amps @ 380 V
L3 - 11.5 Amps
GP8900E
400 - 415 V, 50 / 60 Hz,
3 P+N+E.
12 kW,
L1 - 16.4 Amps
L2 - 16.4 Amps @ 415 V
L3 - 16.4 Amps
GP8120E
400 - 415 V, 50 / 60 Hz
3 P+N+E.
18 kW,
L1 - 24.5 Amps
L2 - 24.5 Amps @ 415 V
L3 - 24.5 Amps
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
For the Refrigeration Cabinet Specifications refer to the Refrigeration Cabinet Installation and Operation Manual supplied
with the appliance.
Summary of Contents for GPB8600E
Page 23: ......