NOTE: 

 

It is most important that this appliance is installed correctly and that operation is correct 

before  use.    Installation  shall  comply  with  local  electrical  and  health  and  safety 

requirements. 

 

This  appliance  shall  be  installed  with  sufficient  ventilation  to  prevent  the  occurrence  of  

unacceptable  concentrations  of  health  harmful  substances  in  the  room,  the  appliance  is 

installed in. 

 

Waldorf Electric Griddles are designed to provide years of satisfactory service and correct installation is  

essential to achieve the best performance, efficiency and trouble-free operation. 

This appliance must be installed in accordance with National installation codes and in addition, in  

accordance with relevant National / Local codes covering electrical and fire safety. 

 

Australia / New Zealand 

AS / NZS3000 

 - Wiring Rules. 

United Kingdom: 

BS 7671 

 - Requirements for Electrical Installations. 

 

Installations must be carried out by qualified persons only.  Failure to install equipment to the 

relevant codes and manufacturer’s specifications shown in this section will void the warranty. 

 

Components having adjustments protected (e.g. paint sealed) by the manufacturer are only to 

be adjusted  by an authorised service agent.   They are  not  to be adjusted  by  the installation 

person. 

 

 

 

Remove all packaging and transit protection from the appliance including all protective plastic coating 

from the exterior stainless steel panels. 

 

Check equipment and parts for damage.  Report any damage immediately to the carrier and 

distributor. 

 

Ensure that the 2 front adjustable feet and rear rollers are securely fitted. 

 

Report any deficiencies to the distributor who supplied the appliance. 

 

Check that the available electrical supply is correct to that shown on the rating plate (Refer to the 

dimension drawings for rating plate location). 

 

 

1. 

Installation must include adequate clearance and ventilation, to prevent dangerous build up of  

combustion products. 

2. 

Never directly connect a ventilation system to the appliance flue outlet. 

3. 

Position the appliance in its approximate working position. 

4. 

The legs / castors must always be fitted to the base of the appliance. 

5. 

Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be  

adjusted by an authorised service agent.  They are not to be adjusted by the installation person. 

 

NOTE:  Do not obstruct or block the appliances flue.  Never directly connect a ventilation system to 

the appliance flue outlet. 

 

 

NOTE:  Only non-combustible materials can be used in close proximity to this appliance. 

Left / Right Hand Side 

100mm 

0mm 

Rear 

50mm 

0mm 

Summary of Contents for GPB8600E

Page 1: ...r a t i o n M a n u a l Electric Griddle GP8600E GP8900E GP8120E 229350 15 For use in GB IE I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l GPL8600E GPL8900E GPL8120E GPB8600E GPB8900E GPB...

Page 2: ...el 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Tol...

Page 3: ...rs Covered in this Specification Electrical Supply Requirements Electrical Connection Installation Requirements Unpacking Location Clearances Assembly Electrical Connection Commissioning Operation Gui...

Page 4: ...refer to the supplier of this appliance to obtain the technical instructions for adapting the appli ance to the conditions for use in that country IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE O...

Page 5: ...sheathed flexible cable and not lighter than ordinary polychloroprene or other equivalent synthetic elastomer sheathed cord as per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g H05 RN F Type The b...

Page 6: ...4 GP L 8600E B GP L 8900E B GP L 8120E B Dimensions for Bench Models Rating Plate Location for this option R R...

Page 7: ...5 GP L 8600E CB Dimensions for Cabinet Base Models Rating Plate Location for this option R GP L 8900E CB GP L 8120E CB R...

Page 8: ...6 GP L 8600E LS GP L 8900E GP L 8120E LS Dimensions for Leg Stand Models Rating Plate Location for this option R R...

Page 9: ...7 GP L 8900E RB GP L 8120E RB Dimensions for Refrigeration Base Models Rating Plate Location for this option R R...

Page 10: ...sed service agent They are not to be adjusted by the installation person Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior stain...

Page 11: ...l Connections in the Specifications section of the manual 3 Remove the control panel to allow connection access for the electrical supply 4 Bring the supply cable up through the grommet at the back of...

Page 12: ...nstructed in the areas of correct operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and as a record of Date of Purchase Date of Installati...

Page 13: ...en the amber neon goes out the desired temperature has been reached and the griddle is ready for use NOTE Turning the control to a higher setting than required will not shorten the heat up time 3 To t...

Page 14: ...plate while this item is still hot as warping and cracking may occur Allow the griddle plate to cool down before cleaning NOTE DO NOT use strong solvents abrasive or caustic detergents as they could...

Page 15: ...leaning material has been entirely removed after each cleaning process Appliance should be switched On briefly to ensure griddle plate is dry Oil or grease should be spread over griddle surface to for...

Page 16: ...Always apply cleaner when the appliance is cold and rub in the direction of the grain c To remove any discolouration use an approved stainless steel cleaner or stainless steel wool Always rub in the...

Page 17: ...wing information The Model Trade Name and Serial Number of the Appliance can be found on the Rating Plate located on the appliance Refer to the Dimensions section For the Refrigeration Cabinet Fault F...

Page 18: ...MBER 227963 OVERTEMP THERMOSTAT 229353 21 31 7 11 22 32 12 3 P3 4 P4 CONTROL PANEL GRIDDLE PLATE 21 31 11 22 32 12 9 9 9 1 1 1 3 2 2 7 7 6 9 9 9 7 6 8 4 4 5 8 10 11 12 EARTH STUD M6 EARTH STUD 3 16 EA...

Page 19: ...MBER 227963 OVERTEMP THERMOSTAT 229353 21 31 7 11 22 32 12 3 P3 4 P4 CONTROL PANEL GRIDDLE PLATE 21 31 11 22 32 12 9 9 9 1 1 1 3 2 2 7 7 6 9 9 9 7 6 8 8 4 4 5 10 10 11 12 EARTH STUD M6 EARTH STUD 3 16...

Page 20: ...2 12 15 16 15 16 REAR SUPPLY ENTRY THERMOSTAT 229146 SWITCH 229145 2 1 P2 P1 NEON AMBER 227963 NEON GREEN 227962 OVERTEMP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4 21 31 11 22 32 12 EARTH STUD M6...

Page 21: ...MP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4 21 31 11 22 32 12 THERMOSTAT 229146 SWITCH 229145 2 1 P2 P1 NEON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4...

Page 22: ...f 2 Blades 233817 Ribbed Plate Scraper Blade Individual Blade 228795 600mm Plinth Kit LS and CB Models only 228799 900mm Plinth Kit LS and CB Models only 228803 1200mm Plinth Kit LS and CB Models only...

Page 23: ......

Reviews: