31
Technical Data
ENG
12. Technical Data
NOTE:
The data given on the rating plate
of the luminaire attached to the connect-
ing cable apply.
12.1 Dimensions
Designation
Value
Luminaire
head
(C)(M)FTL 102 R:
Ø 122.6 x 11.5 mm
(C)(M)FTL 108 R:
116 x 100 x 11.5 mm
Column
FTL 102/108 R
(Double-arm column):
498 + 301 x 24 x 10 mm
MFTL 102/108 R
(Single-arm column):
501 x 24 x 10 mm
CMFTL 102/108 R
(undercabinet):
301 x 24 x 10 mm
Tab. 4: Dimensions.
12.2 Electrical values
Designation
Value
Voltage range
- Luminaire
- Lum
Operating unit
24 V DC
100-240 V AC
Frequency range
Lum
Operating unit
50/60 Hz
Power
consumption
Luminaire:
(C)(M)FTL 102 R: 6 W
(C)(M)FTL 108 R: 6 W
Lum
Operating unit:
(C)(M)FTL 102 R: 8 W
(C)(M)FTL 108 R: 8 W
Operating unit
Power supply unit
Tab. 5: Electrical values.
12.3 Classifications
Designation
Value
Protection class
- Luminaire
- Lum
Operating unit
III
II
Degree of
protection
IP 20
Operating mode
Continuous
operation
Technical safety
check
EN 60598-1
Tab. 6: Classifications.
12.4 Symbols
Symbol
Designation
Protection class
II
Operation with protective
insulation
Protection class III
Operation with safety
extra low voltage (SELV)
CE conformity mark
Disposal in accordance
with the European WEEE
Directive
Tab. 7: Symbols.