![Waitzinger THP 125/42 R 4 XXT User Manual Download Page 75](http://html1.mh-extra.com/html/waitzinger/thp-125-42-r-4-xxt/thp-125-42-r-4-xxt_user-manual_869133075.webp)
S
TARTING
UP
AND
OPERATING
C
HAPTER
7
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
7-5
3
Fig. 7.5 Indicator lamp "Controls On"
The “Controls ON” indicator lamp (
3
) remains on as long
as the ignition is on and the gearbox is set for pump drive.
This function is independent of any Emergency Stop
indication.
The vehicle engine must be running.
7.2.2
Emergency Stop
The machine is fitted with 4 illuminated Emergency Stop buttons, plus an Emergency Stop button on each remote
control pendant.
Each Emergency Stop button immediately switches off all functions and movements (optionally the engine can be
switched off by an Emergency Stop).
The Emergency Stop buttons are located as follows:
•
Control panel desk (Item 1, Fig. 5.2)
•
Boom control block (Item 3, Fig. 5.4)
•
Left hand outrigger controls (Item 2, Fig. 5.5)
•
Right hand outrigger controls (Item 2, Fig. 5.6)
•
Radio remote control (Item 9, Fig. 5.12)
•
Cable remote control (Item 9, Fig. 5.12)
The activated Emergency Stop button is indicated n the control panel by the flashing Emergency Stop indicator
lamp (Item 12, Fig. 5.2) and at the activated Emergency Stop button itself (except for remote control).
After the reason the activating the Emergency Stop button has been rectified, the activated Emergency Stop
button can be released by pulling or twisting.
NOTE:
The controls must be reset after an Emergency Stop by pressing the
“Horn/Reset” rocker switch (Item 6, Fig. 5.2) on the control panel desk.
All functions that were in operation when the Emergency Stop button was pressed must be restarted.