background image

289.805.003 

17

 

Date: 2018-11-28 

Manual operation using the Control Box 

Insert the control box (not included) into the limit switch connector and apply mains power to the 
product. 
 
Procedure: 

State 

Step  Description 

Setup/ 
Adjustment 

Select mode 7 on the MODE switch and set a slow motor speed using the DMX 
address switches, approx. 100 is recommended for setup purpose. 
 

Push the Up (CW) button on the control box and keep it pushed until the desired 
soft-limit top position is reached. 
 

Push the Down (CCW) button on the control box and keep it pushed until the 
desired soft-limit bottom position is reached. 
 

Select mode 8 and set the desired speed using a value between 060 and 512 on 
the DMX address switches (The minimum obtainable speed may vary due to the 
weight of the load). 

Operation 

Push the Up (CW) button and the motor will move to the top position. 
 

Push the Down (CCW) button and the motor will move to the bottom position. 
 

Power 
down 

Return to the top position as this is always the expected position at power-on. In 
case this is not followed, a full setup procedure will need to be done. 
 

Power-on 

Whenever the product is repowered, there should be no need to setup the top 
and bottom positions, provided the product was powered down at the top 
position, and the shaft position was not changed (manually or due to 
transportation). 
 

 

Control box and Hard-limit switch port 

The following table shows the needed connections to the control box port for using the manual 
mode, it also includes the connections for hard-limit switches when desired. 
 

Pin  Control box option  

(mode 7 and 8) 

Hard-limit switch option  
(mode 4, 5 and 6) 

Connector 
LIMIT SWITCH 

GND (COM/Common) 

GND (COM/Common) 

 

Down (CCW) control button input 
(NO/normal open switch type) 

CW(Up) hard-limit switch input 
(NC/normal closed switch type) 

Up (CW) control button input 
(NO/normal open switch type) 

CCW(Down) hard-limit switch input 
(NC/normal closed switch type) 

+5VDC output (optional) 

+5VDC output (optional) 

Note: All inputs are internally pulled-up to +5V, and then activated by a short (externally switch) to the 
GND pin. 

 

 

 

Summary of Contents for 289.701

Page 1: ...WWW WAHLBERG DK AXEL GRUHNS VEJ 3 TELEPHONE 45 86 18 14 20 8270 H JBJERG EMAIL sales wahlberg dk DENMARK Mini Roll Down Series Item No 289 701 Slow Motor and No 289 702 Fast Motor User Manual...

Page 2: ...und fault earth fault protection Before using the Mini Roll Down check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected...

Page 3: ...own is installed in a location where it may cause injury or damage if it falls install as described on page 9 If possible allow enough clearance beneath the Mini Roll Down so it cannot cause any dange...

Page 4: ...NECTOR ON A POWER CABLE 10 DATA LINK 11 TIPS FOR RELIABLE DATA TRANSMISSION 11 CONNECTING THE DATA LINK 11 SETUP 12 MOUNTING THE LOAD 12 MODE SETTING 13 DMX ADDRESS SETTING AND CHANNEL OVERVIEW 13 SET...

Page 5: ...nal DMX 512 1990 DMX512A 6 channels used DMX connection 5 pole XLR male female Slow Motor 289 701 Lifting capacity Load 7 0 kg 15 4 lb Lifting speed 2 5 26 cm sec 1 0 10 2 in sec Motor 24 V DC 54 W Fa...

Page 6: ...289 805 003 6 Date 2018 11 28 Drawing Mini Roll Down Series 289 More detailed drawings can be found in Appendix 1 on page 21...

Page 7: ...peed up to 61 cm s Both versions are highly accurate and stop within 2 mm of the target position Multiple Mini Roll Downs can easily be connected as a chain allowing for advanced and creative ways of...

Page 8: ...age WARNING Read Safety Information on page 2 before installing powering operating or servicing the Mini Roll Down Before applying power to the Mini Roll Down Check the Wahlberg Motion Design website...

Page 9: ...oad Fastening the Mini Roll Down to a flat surface The Mini Roll Down can be fastened to flat surface such as a roof Check that the surface can support at least 10 times the weight of all Mini Roll Do...

Page 10: ...ower plug The Mini Roll Down requires a power input cable with a Neutrik powerCON TRUE1 NAC3FX W cable connector for AC mains power input The cable must meet the requirements listed under Protection f...

Page 11: ...long runs AWG24 cable is suitable for runs up to 100 meters 328 ft Never split a DMX line without using an opto isolated RS 485 splitter amplifier Terminate the link by installing a termination plug i...

Page 12: ...further information and education on DMX protocol Mounting the load When mounting the load make sure it is orientated correctly otherwise the fabric mounted will roll over itself in the wrong directi...

Page 13: ...limits active 7 Manual set soft limit top and bottom position using the control box Manually set run to the soft limit top and bottom positions using the optional control box not included as for stand...

Page 14: ...value of the channel determines the speed at which the Mini Roll Down moves up This channel overrules movement with positioning via channel 1 2 Channel 4 between 60 65 enable save soft limits When ch...

Page 15: ...ow ready for use and the soft limit top and bottom positions have been saved Finally the position control with channel 1 and 2 is now relative to the top and bottom soft limits settings It is recommen...

Page 16: ...ition and 0 is the bottom position The positions lamp indicates by fast flashing that the Mini Roll Down is going towards the wanted position The position lamp indicates by stable light that the Mini...

Page 17: ...er down Return to the top position as this is always the expected position at power on In case this is not followed a full setup procedure will need to be done Power on Whenever the product is repower...

Page 18: ...of multiple Mini Roll Downs If several Mini Roll Downs are installed to perform synchronized movements the best result is achieved by using a fading 16 bit position By nature there is a slight deviati...

Page 19: ...service and maintenance can be provided by the Wahlberg Motion Design giving owners access to Wahlberg Motion Design s expertise and product knowledge in a partnership that will ensure the highest lev...

Page 20: ...cessive use of force the encoding lugs and guide slots in the connector system can become so severely worn or damaged that it is possible to insert the cable connector the wrong way However when inser...

Page 21: ...289 805 003 21 Date 2018 11 28 Appendix 1 Dimensions Mini Roll Down...

Page 22: ...289 805 003 22 Date 2018 11 28 Appendix 2 Power Connector...

Page 23: ...289 805 003 23 Date 2018 11 28...

Page 24: ...Roll Down control system Input output plugs Power out powerCON TRUE 1 Power in 100 240 VAC powerCON TRUE 1 DMX signal out XLR 5 pole DMX signal in XLR 5 pole Control input DMX signal Controller Motor...

Page 25: ...pull channel 5 to 0 when the desired top position is reached 9 Pull channel 6 to 20 the Mini Roll Down starts moving down 10 Stop the Mini Roll Down pull channel 6 to 0 when the desired bottom positio...

Reviews: