Marey Electric Tankless Water Heater by Wahlbach

Marey Electric Tankless Water Heater by Wahlbach

3.  Technical Specifications

Technical specifications

POWER PAK Series

PP4 | PPS4

PP6 | PPS6

Electric supply

110-120V 60Hz

208-240V 60Hz

Nominal power rating

2.9 kW @ 110V

4.5 kW @ 208V

3.5 kW @120V

6 kW @ 240V

Nominal current

27 A @ 110V

22 A @ 208V

29 A @ 120V

25 A @ 240V

Ground fault circuit interrupter

2-POLE 30A

2-POLE 30A

Cable size

12 AWG

12 AWG

Resistivity of the water supply

≥ 3300 Ω•in

≥ 3300 Ω•in

Flow rate (Δt=45°F)

0.5 GPM @120V

0.9 GPM @240V

Flow rate (Δt=65°F)

0.4 GPM @120V

0.6 GPM @240V

Heating system    

Bare element

Bare element

Control unit

Hydraulic | Digital

Hydraulic | Digital

Temperature range

-  |  95 - 122 °F

-  |  95 - 122 °F

Switch on flow rate

0.34 GPM | 0.32 GPM

0.58 GPM | 0.55 GPM

Non-usage consumption

< 1Wh/h

< 1Wh/h

Protection class

IP25

IP25

Unit dimensions

5

 x 7

 x 3

5

 x 7

 x 3

Unit weight

3.0 lb

3.0 lb

Water connections

1/2" NPT

1/2" NPT

Max. inlet water pressure

150 psi

150 psi

Min. inlet water pressure

15 psi

15 psi

Switch on flow pressure

15 psi

15 psi

4.  User Manual

To prevent damage to the appliance, the instantaneous water heater must be 

purged of air before using it for the first time.

How to use (POWER PAK S Series)

The appliance can detect the undersink/oversink installation automatically, and 

make sure the display properly.

LEDs

Touch Keys

Step 0

Switch on the electric power, open the hot-water tap, and wait for a 
short power-up delay (approx. 13 secs).

Step 1

Keep the hot-water tap opening, touch “

” to light on the touch 

keys, then touch “

” again to turn on the appliance. The LED will 

display current outlet temperature setting for 2 secs then switch to 
display the real time outlet temperature.

Step 2

Keep the hot-water tap opening, set desired outlet temperature, 
touch “

” to decrease the outlet temperature or touch “

” to in-

crease the outlet temperature. The LED will keep displaying the 
setting temperature for 2 secs, then switch to display the real time 
outlet temperature. If needed, adjust the water flow rate ( see next 
page).

Step 3

Close the hot-water tap, the LED will light off immediately, the touch 
key “

”, “

” and “

” will light off after 3 secs delay.

Note:

1.   

Step 0

 is only valid after every-time switch off the electric power.

2.  After completing 

Step 3

, opening the hot-water tap again will wake up the 

appliance automatically and the LED will display the real time outlet tempera-
ture.

Summary of Contents for marey PP4

Page 1: ......

Page 2: ...e to observe this instruction may expose you or others to danger Failure to observe this instruction may lead to damage to the device Indicates live parts Failure to observe this instruction may lead...

Page 3: ...UCTORS ONLY USE BONDING CONDUCTOR IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE PART I Each individual heating element is marked with the manufacturer s part number or its electrical rating in volta...

Page 4: ...supply with PPS6 which rated 240V NOTE The wire has been attached to the appliance GR GR L2 L1 Circuit Breaker WIRE Tankless Water Heater Electric Panel 240V 60Hz Please take reference of the followin...

Page 5: ...tallation location of the appliance Make sure the clearance meet the requirement of following diagram Top clearance 4 Bottom clearance 4 Right clearance 4 Left clearance 4 Front clearance 4 Frost The...

Page 6: ...A Installation as undersink model 1 1 2 2 3 3 a Seal b Filter mat c Cold water connection inlet d Hot water connection outlet e Rating plate cover a d b c e 4a Power supply 110 120V Power Supply L N 4...

Page 7: ...er Please verify the voltage of power supply before installation Drawing A B Installation as under over sink model The device must be installed as shown in the installation drawing on the page 10 to 1...

Page 8: ...nt damage to the appliance the instantaneous water heater must be purged of air before using it for the first time How to use POWER PAK S Series The appliance can detect the undersink oversink install...

Page 9: ...ter valve There is a danger of scalding at outflow temperatures exceeding 43 C 109 F Mixer taps and thermostatic mixer taps should be of a design compatible with devices with flow control Fittings for...

Page 10: ...can be accessed by sepa rating the device from the tap Make sure you have switched off the main power supply and the main water supply 6 Troubleshooting First aid Check the leakage protection switch a...

Page 11: ...shall also be excluded under this warranty The warranty will not be valid if the problem is caused by extreme values of drinking water pH value not between 6 5 and 9 5 and or Cl above 150 mg l and or...

Page 12: ......

Reviews: