Wahl Bach marey PP4 Instruction Manual Download Page 3

4

5

EN

EN

Safety Instructions

Safety Instructions

Marey Electric Tankless Water Heater by Wahlbach

Marey Electric Tankless Water Heater by Wahlbach

This product shall be protected by a Class A ground fault circuit interrupter.

This appliance is not intended for use by persons (including children) with re-

duced physical, sensory or mental capabilities, or lack of experience and knowl-

edge, unless they have been given supervision or instruction concerning use of 

the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

The maximum inlet water pressure: 1.0 MPa (150 PSI).

The minimum inlet water pressure: 0.1 MPa (15 PSI).

WARNING

Before obtaining access to terminals, all supply circuits must be disconnected. 

After service work is complete, proceed as during the first-time appliance start-

up.
The connection diagram or wiring diagram is marked. (Located on inside of Front 

Enclosure)

CAUTION

1.  DO NOT INSTALL IN A BATH ENCLOSURE OR SHOWER STALL OR CONNECT TO A 

SALT-  REGENERATED WATER SOFTENER OR A WATER SUPPLY OF SALT WATER

2.  CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIR-

CUIT INTERRUPTER

For use on an individual branch circuit only.

USE COPPER CONDUCTORS ONLY 

USE BONDING CONDUCTOR IN ACCORDANCE WITH THE CANADIAN ELECTRICAL 

CODE, PART I
Each individual heating element is marked with the manufacturer’s part number 

or its electrical rating in voltage and amperes/watts.

The specific spacing between the appliance and adjacent surface.

SAVE THESE INSTRUCTIONS

The appliance is not to be installed in locations where freezing can occur.

The resistivity of the water supply must not be less than 3300 Ω

in.

The appliance must be grounded properly!

The appliance is close-outlet type, the water connection of this appliance must 

be connected to unvented water heating system.

No changes may be made to the appliance.

If the supply cord is damaged, it must be replaced by the manufacturer, its ser-

vice agent or similarly qualified persons in order to avoid a hazard.

Declaration of conformity

We hereby declares that the Marey devices comply with the following standards:
•  CAN/CSA E60335-2-35
•  CAN/CSA-C22.2 No. 60335-1
•  UL 499

Standards and regulations

The installation (plumbing and electrical work), commissioning and maintenance 
of this appliance should only be undertaken by personnel with electrical engi-
neering qualifications and in accordance with the relevant standards and regula-
tions (BSI, etc.) and this manual.
The following should also be observed:
• The appliance name plate;
• The technical specifications.
Connection to the water supply
Compatible cold water pipe materials: steel, copper and plastic.

Summary of Contents for marey PP4

Page 1: ......

Page 2: ...e to observe this instruction may expose you or others to danger Failure to observe this instruction may lead to damage to the device Indicates live parts Failure to observe this instruction may lead...

Page 3: ...UCTORS ONLY USE BONDING CONDUCTOR IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE PART I Each individual heating element is marked with the manufacturer s part number or its electrical rating in volta...

Page 4: ...supply with PPS6 which rated 240V NOTE The wire has been attached to the appliance GR GR L2 L1 Circuit Breaker WIRE Tankless Water Heater Electric Panel 240V 60Hz Please take reference of the followin...

Page 5: ...tallation location of the appliance Make sure the clearance meet the requirement of following diagram Top clearance 4 Bottom clearance 4 Right clearance 4 Left clearance 4 Front clearance 4 Frost The...

Page 6: ...A Installation as undersink model 1 1 2 2 3 3 a Seal b Filter mat c Cold water connection inlet d Hot water connection outlet e Rating plate cover a d b c e 4a Power supply 110 120V Power Supply L N 4...

Page 7: ...er Please verify the voltage of power supply before installation Drawing A B Installation as under over sink model The device must be installed as shown in the installation drawing on the page 10 to 1...

Page 8: ...nt damage to the appliance the instantaneous water heater must be purged of air before using it for the first time How to use POWER PAK S Series The appliance can detect the undersink oversink install...

Page 9: ...ter valve There is a danger of scalding at outflow temperatures exceeding 43 C 109 F Mixer taps and thermostatic mixer taps should be of a design compatible with devices with flow control Fittings for...

Page 10: ...can be accessed by sepa rating the device from the tap Make sure you have switched off the main power supply and the main water supply 6 Troubleshooting First aid Check the leakage protection switch a...

Page 11: ...shall also be excluded under this warranty The warranty will not be valid if the problem is caused by extreme values of drinking water pH value not between 6 5 and 9 5 and or Cl above 150 mg l and or...