17
DE
GB
1. Left outlet of the device is the water outlet (hot/ red), right outlet is the
water inlet (cold/ blue).
2. Prepare the water connections to the tap. Make sure main water supply
is switched off.
3. Prepare the electrical connections for the device. Make sure main power
is switched off.
4. To prepare the connection to the water supply Teflon tape must be used
for sealing the pipes.
5. Mount the tap to the main water supply.
6. Level the tap horizontally.
7. Mount the device to the tap.
8. Open the main water supply and check for leakage and release air from
the system by opening the hot water tap.
9. When air has left the system, plug* in the device to the electric system.
10. Switch on the main power supply.
11. Heater should now function!
* The 4,5kW and 5,5kW model are delivered without plug.
Drawing B. Installation as undersink model
The device must be installed as shown in the installation drawing (B) for under-
sink model on the first page of this manual.
1. Left outlet of the device is the water inlet (cold/ blue), right outlet is the
water outlet (hot/ red).
2. Prepare the water connections to the tap. Make sure main water supply
is switched off.
3. Install the device by using the installation bracket which is supplied with
the device.
4. Connect the water supply to the device and to the main water supply.
5. Prepare the electrical connections for the device. Make sure main power
is switched off.
6. Open the main water supply and check for leakage and release air from
the system by opening the hot water tap.
7. When air has left the system, plug* in the device to the electric system.
8. Switch on the main power supply.
9. Heater should now function!
* The 4,5kW and 5,5kW model are delivered without plug.