background image

 

 

Important Comments 

  

  7 

 

 

Safety Notes 

 

WAGO-I/O-SYSTEM 751 
AS-Interface Components IP67 

1.4 Safety Notes 

 

Attention

 

Switch off the system prior to working on bus modules! 

In the event of deformed contacts, the module in question is to be replaced, as 
its functionality can no longer be ensured on a long-term basis. 

The components are not resistant against materials having seeping and 
insulating properties. Belonging to this group of materials is: e.g. aerosols, 
silicones, triglycerides (found in some hand creams).  
If it cannot be ruled out that these materials appear in the component 
environment, then additional measures are to be taken:  
- handling of the components only with clean tools and materials. 

 

Attention

 

Cleaning of soiled contacts may only be done with ethyl alcohol and leather 
cloths. Thereby, the ESD information is to be regarded. 

Do not use any contact spray. The spray may impair the functioning of the 
contact area.  

 

Attention 

Unused connection sockets must be sealed with filler plugs in order to keep 
IP67 degree of protection! 

 

1.5 Scope 

This manual describes the Digital Input Module 751-4001 
AS-Interface Module 4OUT 24V/2A Single of the m
odular WAGO-I/O-
SYSTEM 751. 

Handling, assembly and start-up are described in the manual of the Fieldbus 
Coupler. Therefore this documentation is valid only in the connection with the 
appropriate manual.

Summary of Contents for I/O-SYSTEM 751-4001

Page 1: ...AS Interface Components IP67 AS Interface Module 4OUT 24V 2A Single 751 4001 Manual Version 1 1 0...

Page 2: ...hone 49 0 571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can...

Page 3: ...ls 6 1 3 Number Notation 6 1 4 Safety Notes 7 1 5 Scope 7 2 AS Interface Components 8 2 1 AS Interface Module IP67 8 2 1 1 751 4001 AS Interface Module 4OUT 24V 2A Single 8 2 1 1 1 View 8 2 1 1 2 Desc...

Page 4: ...10e 8 Fig 2 1 1 2 Actuator Connector gqxxx02x 9 Fig 2 1 1 3 Display Elements gq40012x 10 Fig 2 1 1 4 Schematic View gq40011e 11 Fig 2 1 1 5 Dimensions gqxxx08x 14 Fig 2 1 1 6 Assembly gqxxx10x 15 List...

Page 5: ...ther manufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this...

Page 6: ...oth operation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for e...

Page 7: ...ent environment then additional measures are to be taken handling of the components only with clean tools and materials Attention Cleaning of soiled contacts may only be done with ethyl alcohol and le...

Page 8: ...is an economical solution for a fieldbus independent and flexible connection of actuators from the field and the control cabinet The module is in accordance with AS Interface specification V 3 0 The...

Page 9: ...cting cable The following table shows the pin assignment of the sockets Tab 2 1 1 1 Actuator Connector Actuator Connectors Connector Pin Function 1 not used 2 not used OUT 1 3 OUT 2 4 3 External volta...

Page 10: ...t OUT 3 yellow Status DO3 on Output 3 set off Output 4 reset OUT 4 yellow Status DO4 on Output 4 set off OK on Configuration error FID FAULT red Error blinking Actuator supply is missing or output dri...

Page 11: ...YSTEM 751 AS Interface Components IP67 2 1 1 6 Schematic View AUX AUX AUX AUX 1 4 2 3 5 1 4 2 3 5 IR FE FE AUX AUX ASI FID FAULT NTERFACE OUT1 3 OUT2 4 OUT1 OUT1 OUT3 OUT3 OUT OUT OUT2 OUT2 OUT OUT4 O...

Page 12: ...Current carrying capacity per module max 8 A External voltage supply AUX acc to PELV Rated voltage 24 V 15 20 Connection system socket M12 x 1 5 pole AS Interface Operating voltage AS I 26 5 V 31 6 V...

Page 13: ...o IEC 60068 2 27 EMC Immunity to interference CE acc to EN 61000 6 2 EMC Emission of interference CE acc to EN 61000 6 3 Approvals AS Interface Association Specification V3 0 ZU No 72601 CULUS UL508 C...

Page 14: ...S Interface Module 4OUT 24V 2A Single Technical Data WAGO I O SYSTEM 751 AS Interface Components IP67 Tab 2 1 1 3 Technical Data Dimensions 73 39 33 ASI AUX 54 94 32 24 ASI AUX 4 5 Fig 2 1 1 5 Dimensi...

Page 15: ...n the cutouts that are marked for this purpose Make sure that the cables engage behind the locking latch For modules with unused AUX socket insert the enclosed blanking cap to seal the cable entry 3 F...

Page 16: ...ification may lead to malfunctions or restrictions Please note the AS interface master manual and the manual for the start up tool WAGO I O CHECK 2 759 302 for start up and diagnosis of the AS interfa...

Page 17: ...751 4001 AS Interface Module 4OUT 24V 2A Single 17 Start up and diagnosis WAGO I O SYSTEM 751 AS Interface Components IP67...

Page 18: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Reviews: