background image

 • 

Important Comments 

 Legal 

Principles

 

  

WAGO-I/O-SYSTEM 

750 

  

I/O 

Modules 

1 Important Comments 

To ensure fast installation and start-up of the units described in this manual, 
we strongly recommend that the following information and explanations are 
carefully read and abided by. 

1.1 Legal Principles 

1.1.1 Copyright 

This manual is copyrighted, together with all figures and illustrations con-
tained therein. Any use of this manual which infringes the copyright provi-
sions stipulated herein, is not permitted. Reproduction, translation and elec-
tronic and photo-technical archiving and amendments require the written con-
sent of WAGO Kontakttechnik GmbH. Non-observance will entail the right of 
claims for damages. 

WAGO Kontakttechnik GmbH reserves the right to perform modifications al-
lowed by technical progress. In case of grant of a patent or legal protection of 
utility patents all rights are reserved by WAGO Kontakttechnik GmbH. Prod-
ucts of other manufacturers are always named without referring to patent 
rights. The existence of such rights can therefore not be ruled out. 

1.1.2 Personnel Qualification 

The use of the product detailed in this manual is exclusively geared to special-
ists having qualifications in PLC programming, electrical specialists or per-
sons instructed by electrical specialists who are also familiar with the valid 
standards. WAGO Kontakttechnik GmbH declines all liability resulting from 
improper action and damage to WAGO products and third party products due 
to non-observance of the information contained in this manual. 

1.1.3 Intended Use 

For each individual application, the components supplied are to work with a 
dedicated hardware and software configuration. Modifications are only per-
mitted within the framework of the possibilities documented in the manuals. 
All other changes to the hardware and/or software and the non-conforming use 
of the components entail the exclusion of liability on part of WAGO Kon-
takttechnik GmbH. 

Please direct any requirements pertaining to a modified and/or new hardware 
or software configuration directly to WAGO Kontakttechnik GmbH. 

Summary of Contents for 750-512

Page 1: ...Fieldbus Independent I O Modules 2DO 230V AC 2 0 A Relay 2NO 750 512 Manual Version 1 0 2...

Page 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Page 3: ...Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 I O Modules 7 2 1 Digital Output Modules 7 2 1 1 750 512 2DO 230V AC 2 0 A Relay 2NO 7 2 1 1 1 View 7 2 1 1 2 Description 7 2 1 1 3 Display Elements...

Page 4: ...nufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual...

Page 5: ...ation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for efficient...

Page 6: ...information is to be regarded Do not use any contact spray The spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assemb...

Page 7: ...relay contacts from the control system The module has two output channels Two actuators with ground earth wire may be directly connected to signal output DO 1 N and PE earth potential or signal output...

Page 8: ...10 A When configuring the system it is important not to exceed the maximum sum cur rent However if such a case should occur another supply module must be added Note For the protection of relay coils a...

Page 9: ...2NO 9 Schematic Diagram WAGO I O SYSTEM 750 I O Modules 2 1 1 4 Schematic Diagram DO 2 AC 230 V DC 30 V AC 230 V DC 30 V DO 1 N N 0 V 0 V DO Status 1 2 3 4 5 6 7 8 750 512 Fig 2 1 1 3 2 Channel Relay...

Page 10: ...10 ms Contact material Silver alloy Mechanical life max 2x107 switching operatins Electrical life min 3x105 switching operatins AC 2 A 250 V or DC 2 A 30V Isolation 1 5 kVeff System Field 2 5 kV rate...

Page 11: ...Bureau of Shipping BV Bureau Veritas Conformity Marking More Information Detailed references to the approvals are listed in the document Overview Approvals WAGO I O SYSTEM 750 which You can find on th...

Page 12: ...O Modules 2 1 1 7 Load limiting value graph of the relay 0 0 1 0 3 0 5 1 3 5 10 30 50 3 5 10 30 100 250 500 1000 Switching current A Switching voltage V AC load resistive AC in ductive load cos 0 4 j...

Page 13: ...ar Effective Attenuation Advantages Disadvantages Diode UD Load g051211e long yes UD no Advantages easy implementation cost effective reliable uncritical dimensioning low induction voltage Disadvantag...

Page 14: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Reviews: