1

 

Important Comments ................................................................................. 4

 

1.1 Legal 

Principles........................................................................................ 4 

1.1.1 Copyright ............................................................................................. 4 
1.1.2 Personnel 

Qualification ....................................................................... 4 

1.1.3 Intended 

Use ........................................................................................ 4 

1.2 Symbols .................................................................................................... 5 
1.3 Number 

Notation...................................................................................... 5 

1.4 Safety 

Notes ............................................................................................. 6 

1.5 Scope ........................................................................................................ 6 

2

 

I/O Modules ................................................................................................. 7

 

2.1  Digital Output Modules............................................................................ 7 
2.1.1 

750-512 [2DO 230V AC 2.0 A/ Relay 2NO] ...................................... 7 

2.1.1.1 View................................................................................................ 7 
2.1.1.2 Description...................................................................................... 7 
2.1.1.3 Display 

Elements ............................................................................ 8 

2.1.1.4 Schematic 

Diagram......................................................................... 9 

2.1.1.5 Technical 

Data .............................................................................. 10 

2.1.1.6 Process 

Image ............................................................................... 11 

2.1.1.7 

Load limiting value graph of the relay.......................................... 12 

2.1.2 

Contact Protective Circuit for Relay Modules .................................. 13 

 

 

Summary of Contents for 750-512

Page 1: ...Fieldbus Independent I O Modules 2DO 230V AC 2 0 A Relay 2NO 750 512 Manual Version 1 0 2...

Page 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Page 3: ...Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 I O Modules 7 2 1 Digital Output Modules 7 2 1 1 750 512 2DO 230V AC 2 0 A Relay 2NO 7 2 1 1 1 View 7 2 1 1 2 Description 7 2 1 1 3 Display Elements...

Page 4: ...nufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual...

Page 5: ...ation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for efficient...

Page 6: ...information is to be regarded Do not use any contact spray The spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assemb...

Page 7: ...relay contacts from the control system The module has two output channels Two actuators with ground earth wire may be directly connected to signal output DO 1 N and PE earth potential or signal output...

Page 8: ...10 A When configuring the system it is important not to exceed the maximum sum cur rent However if such a case should occur another supply module must be added Note For the protection of relay coils a...

Page 9: ...2NO 9 Schematic Diagram WAGO I O SYSTEM 750 I O Modules 2 1 1 4 Schematic Diagram DO 2 AC 230 V DC 30 V AC 230 V DC 30 V DO 1 N N 0 V 0 V DO Status 1 2 3 4 5 6 7 8 750 512 Fig 2 1 1 3 2 Channel Relay...

Page 10: ...10 ms Contact material Silver alloy Mechanical life max 2x107 switching operatins Electrical life min 3x105 switching operatins AC 2 A 250 V or DC 2 A 30V Isolation 1 5 kVeff System Field 2 5 kV rate...

Page 11: ...Bureau of Shipping BV Bureau Veritas Conformity Marking More Information Detailed references to the approvals are listed in the document Overview Approvals WAGO I O SYSTEM 750 which You can find on th...

Page 12: ...O Modules 2 1 1 7 Load limiting value graph of the relay 0 0 1 0 3 0 5 1 3 5 10 30 50 3 5 10 30 100 250 500 1000 Switching current A Switching voltage V AC load resistive AC in ductive load cos 0 4 j...

Page 13: ...ar Effective Attenuation Advantages Disadvantages Diode UD Load g051211e long yes UD no Advantages easy implementation cost effective reliable uncritical dimensioning low induction voltage Disadvantag...

Page 14: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...