2789-9023
Fieldbus Description
Product manual | Version: 1.0.0
27
EtherNet/IP Communication Module
Attribute
ID
Access
Name
Data type
Description
Factory setting
3
Get
Number of In-
stances
UINT16
Number of connections currently
instantiated
1
Table 22: TCP/IP Interface Object – Instance 1
Attribute
ID
Access
Name
Data type
Description
Factory setting
1
Get
Status
UINT32
Interface status
2
Get
Configuration Ca-
pability
UINT32
Interface flags for possible con-
figuration types
0x00000054
3
Get/Set
Configuration
Control
UINT32
Determines how the product cou-
pler arrives at its TCP/IP configu-
ration after the first restart
0x00000002
4
Get
Physical Link Ob-
ject
STRUCT of:
Path Size
UINT16
Number of 16 bit words in the
subsequent path
0x0002
Path
Padded
EPATH
Logical path that points to the
physical link object
0x20, 0xF6,
0x24, 0x01 (cor-
responds to the
Ethernet Link Ob-
ject)
5
Get/Set
Interface Config-
uration
STRUCT of:
IP Address
UINT32
IP address
192.168.1.17
Network Mask
UINT32
Network mask
255.255.255.0
Gateway Ad-
dress
UINT32
IP address of the default gate-
way
192.168.1.1
Name Server
UINT32
IP address of the primary name
server
0
Name Server 2
UINT32
IP address of the secondary
name server
0
Domain Name
CHAR[32]
Default domain name
6
Get
Host Name
CHAR[32]
Device name