GB
22
WallPerfect W 665
Problem
Cause
Remedy
Paint in the
ventilating hose
Diaphragm soiled
•
Diaphragm defective
•
Clean the diaphragm
➞
Replace the diaphragm
➞
Poor covering
capacity on the wall
Spray material is too cold
•
Highly absorbent surface
•
or paint with poor covering
capacity
Distance too large
•
Heat spray material
➞
(to
maximum 40°C)
Cross spray (Fig. 13)
➞
Closer to the object
➞
Warning
If the supply cord of this appliance is
damaged, it must only be replaced
by a repair shop appointed by the
manufacturer, because special purpose
tools are required.
Warning: Do not connect the blue
or brown wire to the earth
terminal of the plug! The
wires in this mains lead are
coloured in accordance with
the following code:
blue = neutral brown = live
As the colours of the wires in the mains lead of this appliance may not correspond with
the coloured markings identifiying the terminals in your plug, proceed as follows:
Should the moulded plug have to be replaced, never re-use the defective plug or
•
attempt to plug it into a different 13 A socket. This could result in an electric shock.
Should it be necessary to exchange the fuse in the plug only use fuses approved by
•
ASTA in accordance with BS 1362. 5 Amp fuses may be used.
To ensure that the fuse and fuse carrier are correctly mounted please observe the
•
provided markings or colour coding in the plug.
After changing the fuse, always make sure that the fuse carrier is correctly inserted.
•
With out the fuse carrier, it is not permissible to use the plug.
The correct fuses and fuse carriers are available from your local electrical supplies
•
stockist.