5
DESCRIPTION
5.1
AREAS OF APPLICATION
Incorrect use!
Risk of injury and damage to the device.
Only connect original Wagner spray guns to the VM 500 control unit.
Only connect the GM 5000EA or GM 5000EAC spray guns.
WARNING
The VM 500 control unit, together with the matching GM 5000EA or GM 5000EAC spray
gun and other components, form an electrostatic hand spray system. The VM 500 supplies
the control voltage for the spray gun, in which high-voltage is subsequently produced. The
high-voltage supply is switched on and off with the trigger of the spray gun.
The special linear characteristic for high-voltage ensures that if the spray gun is brought
too close to the work piece (or to earth) the high-voltage is reduced automatically to
prevent an accidental spark discharge.
The VM 500 control unit also off ers a fault display.
5.2
FUNCTIONAL DESCRIPTION
Input voltage
115 VAC – 240 VAC, 50 Hz / 60 Hz
Input power
max. 40 W
Input current
max. 0.5 A
Output voltage
max. 20 Vpp
Output current
max. 1.0 A AC
High-voltage limiting
70 kV DC
Spray current limiting
100 μA DC
Polarity
for negative high-voltage generators
Protection class
IP 54 *
Weight (without cables)
2.3 kg; 5.07 lbs.
Operating temperature range
0 – 40 °C; 32 – 104 °F
* Splash water protection is only guaranteed when the gun cable socket is screwed to
the device plug and the mains cable plug is fi xed to the control unit plug with the
safety clip.