UV-C 75W TIMER |
9
EN
UV-C 75W TIMER MANUAL
HOW IT WORKS
Inside the reactor a UV-C lamp produces radiation with a wavelength of 253.7 nm. Radiation of this type
kills bacteria, viruses, algae and fungi (e.g. Legionella and Cryptosporidium). The UV-C unit produces
clean, fresh, clear water in an efficient, environmentally friendly way. The water is fed through the
UV-C device by a pump. The UV-C radiation neutralizes bacteria, viruses and other micro-organisms
and prevents them from reproducing. Floating algae is also destroyed by this radiation, which greatly
improves the clarity of the water. The UV-C unit is equipped with an electronic ballast. This ballast
ensures optimum performance of the lamp.
In addition, the stainless steel reactor reflects the UV-C radiation, increasing efficiency by up to 35%.
Thanks to the UV-C unit, the water is disinfected efficiently and safely, providing you with excellent water
quality. Overdosing with UV-C is not possible.
INSTALLATION OF EARTHING (DRAWING 1)
1. Before the plastic strain relief (4) is fitted on the earthing bolt (1), first pull the cable (2) through the
strain relief (4). Place the strain relief (4) about 10 cm from the eye (2) of the earthing cable.
2. Place the eye (2) of the cable over the earthing bolt that is attached to the housing.
3. Then place a serrated lock washer (3).
4. Attach the strain relief (4) to create a Ø5 cm loop.
5. Finally, place the second serrated lock washer (5) and the lock nut (6) on the earthing bolt.
6. Once the parts have been placed on the earthing bolt in the correct order, it can be tightened with
an 8 mm open-end or ring spanner.
CAUTION:
Carefully read these instructions before installing this device.
Always make sure to have a correct
grounding. When in doubt about the
grounding of the electrotechnical installation
in general, always consult a licensed
electrotechnical mechanic. Faulty grounding
can be dangerous, and/or lead to corrosion
of stainless steel or aluminium reactors.
It’s not permitted to flow a liquid through
the reactor or to add additions to the
water that has to be treated, which can
have a negative effect on corrosion
or degradation on the used materials.
This to avoid dangerous situations or
damage to the reactor and surrounding
installations and/or to the flora and fauna.
Radiation of this ultraviolet lamp is
dangerous for eyes and skin.
Always free the device of tension
first during maintenance! Risk of an
electric shock. Connect only to a
grounding type receptacle protected
by a ground- fault circuit-interrupter
(GFCI). Do not use an extension cord.
The quartz glass and the UV-C lamp will
stay warm for quite some time after the
device has been switched off. It has a
cooling time of at least 15 minutes.
Wear gloves to protect the quartz glass
and UV-C lamp against fingerprints.
Fingerprints can burn into the quartz
glass and UV-C lamp while turned on,
causing reduction of the disinfection.
The UV-C lamp should never be
turned on when there’s no flow.
Wear safety glasses during
maintenance and installation.
Please read through these instructions for use
carefully before installing this device.