33
VERSION 01/2021
ORDER NUMBER DOC2422004
TOPFINISH Bell 1S ECH
B_07442
Minimum distance in mm
Work piece
Sparkovers may arise for reasons other than electric charges from the device itself. To
prevent sparkovers, conductive work clothes (conductive safety boots and gloves) must
also be worn.
6.7.1 ASSEMBLY OF HIGH-SPEED ROTARY ATOMIZER ON RECIPROCATOR
The high-speed rotary atomizer can flexibly be mounted.
The TOPFINISH Bell 1S ECH can be mounted to a reciprocator or a fixed holder with
corresponding fastening elements.
The high-speed rotary atomizer has three lines for the media (product M, flushing agent FB
and return/circulation DM).
Cover dump outlets that are not used with corresponding valve plugs.
Connecting flange
Reciprocator
B_07438
Material needed:
a) Pre-assembled hose sets for product, air, high voltage and optical fiber (see Chapter
)
or
a) 4x air hose 4/2.7 mm, of appropriate length
1x air hose , 6/4 mm, of appropriate length
5x air hose 8/6 mm, of appropriate length
b) Pre-assembled high-voltage cable (high-voltage cable and connector plug) (see
Chapter
) of appropriate length
c) Optical fiber (see Chapter
)
d) Product line of the appropriate length
e) Dump line (waste line) of the appropriate length
f) Flushing agent line for flushing the bell plate of the appropriate length
g) Grounding cable of the appropriate length
Grounding