45
Super Finish 17ex
GB
CLEANING THE UNIT
8
CLEANING THE UNIT
A clean state is the best method of ensuring operation without
problems. After you have finished spraying, clean the unit. Un-
der no circumstances may coating material rests dry and harden
in the unit. The cleaning agent used for cleaning must be suit-
able for the coating material used.
Warm water improves the cleaning effect in the
case of water-dilutable coating materials.
•
Secure the spray gun
, refer to the operating manual of the
spray gun.
Remove and clean the tip.
•
Unit with suction system
1. Set multifunction switch to
(ON - circulation).
2. Remove suction tube from the material container, the re-
turn tube remains over the material container.
3.
Immerse the suction system into a container filled with a
suitable cleaning agent
4. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
In AirCoat mode,
set the AirCoat regulator (5) to 0.
5. Set multifunction switch to
(spray).
6. Pull the trigger guard of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).
The container must be earthed in case of coat-
ing materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
7. Set multifunction switch to
(ON - circulation).
8. Pump suitable cleaning agent in the circuit for several min-
utes.
The cleaning effect is increased by alternatively
opening and closing the spray gun.
9. Set multifunction switch to
(spray).
10. Pump the remaining cleaning agent into an open container
until the pump is empty.
11. Switch off the unit
•
Unit with upper hopper
1. Set multifunction switch to
(ON - circulation).
2. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
3. Set multifunction switch to
(spray).
4. Pull the trigger guard of the spray gun in order to pump
the remaining coating material from the hopper, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
5. Fill up hopper with suitable cleaning agent.
6. Set multifunction switch to
(ON - circulation).
7. Pump suitable cleaning agent in the circuit for several
minutes.
8.
Switch off unit