25
VERSION 01/2020
ORDER NUMBER DOC2397091
SprayPackE
5.6
CPE/CPE-S CONNECTIONS IN HOUSING
DANGER
Danger from electric current!
Danger to life and equipment damage.
The system may only be connected by skilled electricians.
Operate according to the safety regulations, fire protection and electrotechnical
regulations.
Must be de-energized before work is commenced on active parts.
The cable positions 5, 7 and 9 must be inserted into the housing and connected in the housing.
The rear panel can be released and folded down for this purpose.
P_03727
5
9
7
P_03728
Procedure:
1.
Loosen and unscrew screws (7x) on the rear panel.
2.
Carefully fold down rear panel.
3.
Insert cable position 9 with current supply through
the M20 cable gland and connect.
4.
Insert cable position 7 with Wago plug through the
split cable gland and plug in.
5.
Insert cable position 5 through the M16 cable gland
and connect.
6.
Ensure that all fuses are activated.
7.
Once all cables have been connected, carefully fold
the rear panel shut and correctly screw down with
the screws (7 x).