8.6.2
FITTING THE ANGLE ADAPTER
Procedure:
1.
Install electrode holder 1 together with nozzle 2
in nozzle insert 3 and tighten union nut 4.
2.
Push angle adapter 5 onto the gun body and
gently screw threaded sleeve 6.
3.
Swivel angle adapter 5 into the desired position
and then tighten threaded sleeve 6 well.
8.6.3
REPLACEMENT OF THE WEARING PARTS
Procedure:
1.
Loosen threaded sleeve 1 and separate angle
adapter 2 from gun body 3.
2.
Loosen union nut 4.
3.
Pull out electrode holder 5, together with
nozzle 6, from nozzle insert 7.
Note:
Do not damage the electrode holder, when pulling it
out and inserting it.