22
GM 4700AC
B_02261
x
A
B
C
D
B_02383
OPERATING MANUAL
VERSION 09/2011
ORDER NUMBER DOC
2311730
5.4.3
CHANGING THE AIRCOAT NOZZLE
1.
Relieve the pressure of gun and unit.
2.
Secure gun with locking device.
3.
Screw off union nut (A).
4.
Remove air cap (B).
5.
Press AirCoat nozzle (C) out of air cap (B) by hand and treat with cleaning solvent
until all remaining paint has been dissolved.
6.
Assembly:
Place AirCoat nozzle (C) in nozzle seal (D).
7.
Fit air cap (B) over nozzle (C). Take care with the fl attened parts (X) of the nozzle
and of the air cap.
8.
Fit the union nut with nozzle guard (A) and tighten by hand.
CAUTION
Defective AirCoat nozzle!
Insuffi
cient paint application quality.
Do not use sharp-edged objects to treat hard metal on the AirCoat nozzle.