32
GM 4700AC
4
1
3
2
14(F)
13
36
33
B_02390
OPERATING MANUAL
VERSION 09/2011
ORDER NUMBER DOC
2311730
1.
Decommissioning work and cleaning
2.
Relieve the pressure of gun and unit.
3.
Secure gun with locking device.
4.
Unscrew the union nut with nozzle guard (33).
5.
Remove air cap (36) and nozzle (13).
6.
Remove defective sealing ring (14/F) with the help of pipe tongs or with a large
screwdriver.
7.
Assembly: Fit new distributor seal (14/F) to air cap (36).
8.
Place air cap, together with sealing ring (14/F), in gun body.
9.
Attach union nut (33) and screw in until the sealing ring snaps into place in the
mounting groove (audible snap).
10. Demount union nut (33) and air cap (36) and complete spray gun according to
paragraph 5.4.3.
6.6
REPLACING THE "AIR" SEALING RING
CAUTION
Shaping air and atomizer air not separate!
Poor spray pattern
Spray jet cannot be adjusted.
Treat the distributor seal (F) with care.